Part 1 - California Building Code


15.04.600 - CBC Section 105.2 amended.

In Section 105.2 of the California Building Code, modify the beginning of item 6 to read "Platforms, sidewalks, and driveways not more than ...."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.601 - CBC Section 310.1 amended.

In Section 310.1 of the California Building Code, remove Live/Work units from the R-2 listing, and refer to section 15.04.696 of this Code.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.602 - CBC Section 406.1.4 amended.

In Section 406.1.4 of the California Building Code, replace paragraph numbers 1 and 3 in their entirety with the following:

1.  A Group U private garage shall be separated from the dwelling unit and its attic area by not less than ⅝ inch Type X gypsum wallboard or equivalent applied to the garage side of the separation. Door openings shall be protected either with a minimum 1⅜ inches thick solid core wood or solid or honey comb core steel door or with a door complying with section 715.4.3. Doors shall be self-closing and self-latching and shall not connect with a sleeping room. Window openings are prohibited.

3.  A separation between a Group U private carport and the dwelling unit is not required provided the carport is entirely open on two or more sides and there are no enclosed areas above. Door openings shall be protected with a minimum 1⅜ inches thick solid core wood or solid or honey comb core steel door. Window openings shall be fixed (non-openable) and dual-pane tempered glazing. Door and window openings shall not connect with a sleeping room.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.603 - CBC Section 419 deleted and replaced.

Replace Section 419 in the California Building with section 15.04.696 (live/work units) of this Code.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.604 - CBC Section 501.2 amended.

In Section 501.2 of the California Building Code, add the following two sentences:

 "Such building numbers shall be in accordance with the Oakland Municipal Code. In the Very High Fire Hazard Severity Zone, the numbers shall be a minimum of six inches high with a minimum stroke of 0.5 inch."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.605 - CBC Section 506.4 amended.

In the Exception of Section 506.4 of the California Building Code, modify the next to last sentence as follows:

 "A single basement need not be included in the total allowable building area, provided such a basement does not exceed the building area permitted for a building with no more than one story above grade plane."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.606 - CBC Section 507 amended.

In Section 507 of the California Building Code, replace "area" with "building area."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.607 - CBC Section 602.1 amended.

In Section 602.1 of the California Building Code, add the following two new paragraphs:

 "In an existing building where a retrofit seismic bracing system is to be installed, if the existing lateral bracing system is intact and undamaged and the retrofit system is providing bracing to meet current code standards then, the retrofit lateral bracing system is not considered as part of the structural frame for the purposes of this chapter. However, if the retrofit bracing system is connected, through bolts or welding, directly to an existing steel structural frame which permits a path of heat transfer through conduction to the structural steel frame, and the existing structural steel frame is required to meet a one hour or higher fire-resistive requirement, then the retrofit frame shall be one hour minimum fire-resistive.

 In an existing building where a retrofit seismic bracing system is to be installed, if the existing lateral bracing system has been or is to be removed or has been damaged and no longer has its original lateral capacity, then the retrofit lateral bracing system is considered as part of the structural frame and shall meet the appropriate fire-resistive code requirements for the structural frame."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.608 - CBC Section 602.2 amended.

In Section 602.2 of the California Building Code, add the following new paragraph:

 "When a sliding door is otherwise permitted by code and an unlabeled door is also permitted, a pocket sliding door constructed of wood may be used in a Type I and Type II construction as long as the perimeter of the pocket door construction abutting the interior of the wall construction is fire blocked or constructed with a fire-resistive separation in accordance with code. The pocket portion of the pocket sliding door is then considered as part of the door and not a part of the wall construction."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.609 - CBC Section 501.2 amended.

In Section 602.3 of the California Building Code, add the following new paragraph after the second paragraph:

 "When a sliding door is otherwise permitted by code and an unlabeled door is also permitted, a pocket sliding door constructed of wood may be used in Type III construction as long as the perimeter of the pocket door construction abutting the interior of the wall construction is fire blocked or constructed with a fire-resistive separation in accordance with code. The pocket portion of the pocket sliding door is then considered as part of the door and not part of the wall construction."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.610 - CBC Section 602.4 amended.

In Section 602.4 of the California Building Code, add the following new paragraph:

 "When a sliding door is otherwise permitted by code and an unlabeled door is also permitted, a pocket sliding door constructed of wood may be used in Type IV construction as long as the perimeter of the pocket door construction abutting the interior of the wall construction is fire blocked or constructed with a fire-resistive separation in accordance with code. The pocket portion of the pocket sliding door is then considered as part of the door and not part of the wall construction."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.612 - CBC Section 602.5 amended.

In Section 602.5 of the California Building Code, add the following new paragraph:

 "When a sliding door is otherwise permitted by code and an unlabeled door is also permitted, a pocket sliding door constructed of wood may be used in Type V building as long as the perimeter of the pocket door construction abutting the interior of the wall construction is fire blocked or constructed with a fire-resistive separation in accordance with code. The pocket portion of the pocket sliding door is then considered as part of the door and not part of the wall construction."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.614 - CBC Section 702 amended.

In Section 702 of the California Building Code, add the following new definitions:

CABLE: Uninsulated non-ferrous electrical conductors that are a component of a premises wiring system in accordance with the provisions of the California Electrical Code.

VENTS: Plumbing vents that are a component of a sanitary drain waste and vent system in accordance with the provisions of the California Plumbing Code.

WIRES: Uninsulated non-ferrous conductors that are a component of a premises wiring or communication system in accordance with the provisions of the California Electrical Code.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.616 - CBC Section 704.6 amended.

In Section 704.6 of the California Building Code, add the following new paragraph:

 "Supports and hangers for piping, mechanical equipment, and/or other appurtenances shall not be attached to structural members unless the appropriate fire protection of the structural member can be maintained."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.618 - CBC Section 708.3 amended.

In Section 708.3 of the California Building Code, replace this section in its entirety with the following:

 "The shaft enclosure shall be of materials permitted by the building type of construction and shall also have an approved lining or ducted exhaust when used to convey moisture-laden air or product-conveying air, fumes, vapors, or dust in accordance with the provisions of the California Mechanical Code and the California Fire Code."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.622 - CBC Section 716.5.3 amended.

In Section 716.5.3 of the California Building Code:

A.

Delete Exception number 1 in its entirety; and

B.

Add ."..and fire dampers..." after the phrase ."..smoke dampers..." and add ."..which are vented to the outside..." after the phrase ."..at penetrations of shafts..." in the first sentence in Exception number 2; and

C.

Add ."..909.10, and 909.12..." in Exception number 2.3 after the phrase ."..in accordance with the provisions of Sections 909.11...."

D.

Replace Exception number 3 in its entirety with "In parking garages, smoke dampers and fire dampers are not required at penetrations of exhaust shafts or supply shafts of 2-hour fire-resistive construction that have no openings which communicate with other building occupancies."

E.

Add ."..and fire dampers..." in the first sentence in Exception number 4.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.624 - CBC Section 701A.3.1 amended.

In CBC Section 701A.3.1, Item 2, add the following new sentence:

 "All buildings shall comply with all sections of Chapter 7B."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.626 - CBC Chapter 7B added.

Add the following new Chapter 7B for Construction in the Very High Fire Hazard Severity Zone:

Chapter 7B
SPECIAL REQUIREMENTS FOR CONSTRUCTION
IN THE VERY HIGH FIRE HAZARD SEVERITY ZONE

Section 701B Fire Resistance of Walls.

 Notwithstanding any other requirements to the contrary, exterior walls of structures shall comply with the provisions of the California Building Code and with the following requirements:

(1)  If 50% or more of the wall requires repair or replacement, the entire wall shall conform to this section and all other relevant provisions of this code. The exterior wall surface materials, other than ⅞" three-coat stucco, must have a tightly sealed under-layment of ½" Type "C" gypsum sheathing under ⅜" plywood siding or ¾" drop siding, ⅝" Type "X" under other siding, or an approved alternate. If the wall covering is wood shingle, it may only be replaced with fire-retardant, pressure-treated wood shingle applied over the fire resistant construction wall covering described above and only in conjunction with a vegetative management program. Wood shake wall covering shall not be allowed.

(2)  All exterior walls are required to be protected with double blocking (two - 2 inch nominal solid blocking) or equivalent approved by the Building Official between rafters at all roof overhangs under the exterior wall covering. No attic ventilation openings or ventilation louvers shall be permitted in soffits, cave overhangs, between rafters at eaves, or other overhanging areas unless approved by the building official. Attic or foundation ventilation louvers or ventilation openings in vertical walls shall not exceed one hundred and forty-four (144) square inches per opening and shall be covered with ¼ inch mesh corrosion resistant metal screen. Attic ventilation shall also comply with the requirements of the California Building Code.

(3)  If less than 50% of the wall requires repair or replacement, the existing wall may be repaired or replaced in-kind. If the wall covering is wood shingle or wood shake, it may only be repaired or replaced with fire-retardant, pressure-treated wood shingle.

(4)  For enclosed patio covers, enclosed decks, sun rooms, and solariums where the wall between the living area and the enclosure is more than 50% open, the exterior horizontal and vertical surfaces shall meet the requirements as provided in the California Building Code. If the wall between the living area and the enclosure is less than 50% open, that wall must meet the fire-resistive requirements as provided in the California Building Code. The exterior horizontal and vertical surfaces of the enclosure may be constructed of any approved materials and/or methods pursuant to this section or other provisions of this code as long as the attachment of such structures to the fire-resistive wall maintains the fire-resistive integrity of the wall.

Section 702B Fire Resistive Projections and Minor Structures.

 Notwithstanding any other requirements to the contrary in this code, projections from structures in the Very High Fire Hazard Severity Zone without walls, including, but not limited to decks, balconies, roof overhangs, carports and attached patio covers, may be constructed of any approved materials and/or methods pursuant to this section or other provisions of this code. The attachment of these projections to the exterior fire-resistive wall shall be constructed so as to maintain the fire-resistive integrity of the wall.

Section 703B.1 Roof Covering.

 The roof covering assembly includes the roof deck, under-layment, inter-layment, insulation and covering which is assigned a roof-covering classification.

Section 703B.2 Fire Resistive Roof Covering.

 Roof covering on structures shall be fire resistive and shall be as follows:

 Roof covering for newly constructed structures and existing structures for which the roof covering is replaced shall be a minimum Class A rated roof assembly. An existing roof covering with greater than 25% damage of the roof area shall be completely replaced or covered with an assembly having a minimum Class A rating. A Class A roof covering shall be one of the following roofing:

(1)  Any Class A roofing assembly;

(2)  Fibrous cement shingles or sheets;

(3)  Exposed concrete slab roof;

(4)  State shingles;

(5)  Clay or concrete roof tile;

(6)  Roof coverings of wood shingle or shake with less than 25% damage of the roof area shall be repaired with pressure-treated fire-retardant wood shingle or shake with a Class A rating or with any other Class A rated roof covering.

 Roof coverings of other roof material as identified in the California Building Code with less than 25% damage of the roof area may be repaired with the same roof material unless the repair will adversely affect the existing structural members or create or perpetuate an unsafe or substandard condition.

EXCEPTIONS:

(1)  Wood Shingles shall be not less than Class C as provided by the California Building Code or other approved systems in areas designated as Fire Hazard Severity Zones by the Chief of the Fire Department.

(2)  Wood Shakes shall be not less than Class C as provided by the California Building Code or other approved systems in areas designated as Very High Fire Hazard Severity Zones by the Chief of the Fire Department.

Section 703B.3 Roof Covering Application Requirements.

 In addition to any other requirements imposed by this section, application of roof covering materials in the Very High Fire Hazard Severity Zone shall comply with the requirements contained herein.

A.  Existing roof covering with greater than 25% damage of the roof area and existing roof covering which is to be replaced shall be completely removed prior to the application of the new roof covering material.

EXCEPTION:

 Existing roof covering material need not be completely removed prior to the application of the new roof covering material if the existing roof covering material is of Class A rating and contains no wood products and the owner can demonstrate to the Building Official that the roof framing construction can structurally support the combined weight of the existing roof covering material and the new Class A roof covering material.

B.  The vendor of roof covering material shall provide certification of the roof covering material classification to the building owner. The building owner must provide such certification to the Building Official upon inspection.

C.  Repair or replacement of "flat" roof coverings shall not begin until authorized by the Building Official. Where evidence of ponding of water is present, an analysis of the roof structure for compliance with the California Building Code shall be made. The Building Official may require that corrective measures be made.

EXCEPTION:

 An inspection by the Building Official to verify the existing conditions may be waived if the structure owner submits an inspection report prepared by a qualified Special Inspector, approved by the Building Official.

Section 704B.

 Buildings or building groups shall be located at least thirty (30) feet apart to minimize fire spread potential. This may be reduced to a minimum of six feet for each building or group of buildings provided all exterior walls within thirty (30) feet of another building or group of buildings are one-hour fire resistive construction or equipped with an approved automatic fire extinguishing system. The distance shall be measured at right angles from the adjacent building. This provision shall not apply to walls at right angles to the adjacent building or group of buildings.

Section 705B.

 Combustible projections located where openings are not permitted or where protection of openings is required shall be of one-hour fire-resistive or heavy-timber construction conforming to the provisions of the California Building Code.

Section 706B Group R Occupancies.

 All new or reconstructed dwelling units shall be equipped with an approved automatic fire extinguishing system.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.628 - CBC Section 1008.1.1 amended.

In Section 1008.1.1 of the California Building Code, replace Exceptions 1 and 5 in their entirety with the following:

EXCEPTIONS:

1.  Door openings in a dwelling unit or sleeping unit which are not part of the required means of egress and which serve occupiable spaces shall be not less than twenty-eight (28) inches in width.

5.  Door openings in a dwelling unit or sleeping unit which serve occupiable spaces shall not be less than eighty (80) inches in height.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.630 - CBC Section 1008.1.1 amended.

In Section 1008.1.1 of the California Building Code, delete Exceptions 6 and 7 in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.632 - CBC Section 1013 amended.

In Section 1013 of the California Building Code, add the following new subsection:

1013.7 Tensioned Cables.

 Spaced intermediate tensioned cables in guards (guardrails) shall not be considered as meeting the requirements of this section.

EXCEPTION:

 A private dwelling unit with less than 10 occupants may use intermediate tensioned cables in guardrails to meet the requirements of this section if the tension cables are spaced no more than two and one-half inches on center and are positively anchored at each end, and if anchored to wood rely only on compression in the wood to resist the tension in the cable.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.636 - CBC Section 1027.6 amended.

In Section 1027.6 of the California Building Code, delete the phrase ."..for a Group E occupancy..." from the first sentence in the Exception and delete the first sentence beginning "For other than Group E buildings..." in its entirety from the number 2 Exception.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.638 - CBC Section 1029.5.2 amended.

In Section 1029.5.2 of the California Building Code, delete the word "ladder" throughout this section.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.640 - CBC Section 1203.4.1 amended.

In Section 1203.4.1 of the California Building Code, add the following new subsection:

1203.4.1.3 Closets.

 The ventilation for a domestic clothes washer and/or dryer located in a closet in a dwelling unit may also comply with the following:

1.  The area of a closet containing a washer and/or dryer shall be included in the area under consideration for determining ventilation requirements for the room to which the closet is accessory. In the case where a closet containing a washer and/or dryer is located in a hallway, the area of closet and hallway shall be included in the area under consideration for determining ventilation requirements for the room or rooms which will provide the ventilation to the hallway and closet.

2.  Louvers shall be provided on doors to a closet containing a washer and/or dryer.

3.  Natural ventilation shall be not less than one twentieth of the total floor area, with a minimum of 1½ square feet. Mechanical ventilation of five air exchanges per hour may be provided as an alternative.

4.  A dryer vent installed in accordance with the California Mechanical Code is necessary but is not considered as providing any ventilation required by this section.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.642 - CBC Sections 1505.1.1 and 1505.1.3 amended.

In Section 1505.1.1 and 1505.1.3 of the California Building Code, add the new sentence:

 "The roof covering shall include the roof deck, under-layment, inter-layment, insulation and weather-exposed covering which is assigned a roof-covering classification."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.646 - CBC Chapter 16B amended.

Add the following new Chapter 16B for requirements for Private Driveway Access Bridges:

Chapter 16B
PRIVATE DRIVEWAY ACCESS BRIDGES

Section 1601B—Driveway Bridge Design and Repair.

 Every driveway bridge and portion thereof for vehicular access to private garages or private parking shall be designed and constructed as a minimum in accordance with the general requirements of this Code as amended by this Section.

 This Section provides design loading for driveway bridges, driveway approach decks, garage floors, and carport floors. Secondly, this division provides for minimum prescriptive requirements for alterations or repairs of varying scope to existing driveway bridges. This Section considers the possibility of temporary heavy loads on unroofed vehicle approach decks due to construction equipment, moving vans, and heavy emergency or other vehicles using the deck. On these bases, the appropriate design loads have been determined.

 In all cases lateral loads for wind or seismic shall be considered and provided for. Repairs and alterations of existing decks shall conform to the criteria pursuant to this chapter.

Section 1602B - Design Loads

Section 1602B.1 Case I.

 Design loads for driveway bridges serving private residential parking garages/carports with restricted headroom and no repair or refueling. Design loads shall be pursuant to Chapter 16 of the California Building Code for concentrated load and uniform live load (Private or pleasure-type motor vehicle storage). Reduction of live load may be determined pursuant to Chapter 16 of the California Building Code. Design load summary as follows:

 Wheel load:

Two (2) 2,000 lb. loads spaced five (5) feet apart.

 Each concentrated load is to be placed upon any space a maximum of two and a half (2 ½) feet square pursuant to Chapter 16 of the California Building Code.

 Uniform load:

One hundred (100) PSF with no allowable stress increase for duration of load. Live load reduction may be pursuant to Chapter 16 of the California Building Code.

Section 1602B.2 Case II.

 Design loads for private vehicle access bridges serving a single family dwelling on a single lot fronting unimproved streets where the length of the building access path crossing the driveway bridge is fifty (50) feet or less. The following loads apply to the portion of such vehicle access bridges in the public right-of-way as well as the portion on private property. Pursuant to Chapter 16 of the California Building Code, this Section considers the gross weight of the maximum vehicle served to be twenty thousand (20,000) pounds for this condition (AASHTO H10 loading). The length of the access path is measured from the edge of pavement of the unimproved street to the building/garage/carport entry point. This concentrated load may be distributed in accordance with the provisions Chapter 16 of the California Building Code or, alternatively, the concentrated loads may be distributed in accordance with the Standard Specifications For Highway Bridges, 14th ed., 1989, or latest edition, as adopted by the American Association of State Highway and Transportation Officials, 444 North Capital street, N.W., Suite 225, Washington, D.C. 20001. Allowable stress increases for a load duration of seven (7) days may be used for this concentrated load.

 A minimum uniform live load of one hundred (100) PSF, (Garages—General storage and/or repair of the California Building Code), shall be used. Reduction of live loads may be determined pursuant to Chapter 16 of the California Building Code. The condition of concentrated or uniform live load producing the greater stresses shall govern. The summary of these loads are as follows:

Wheel load:

Two (2) 8,000 lb. loads spaced five (5) feet apart.

Each concentrated load is to be placed upon any space a maximum of two and a half (2 ½) feet square.

May alternatively use AASHTO load distribution.

Uniform load:

One hundred (100) PSF with no allowable stress increase for duration of load. Live load reduction pursuant to Chapter 16 of the California Building Code.

Section 1602B.3 Case III.

 Same As Case II, except building entry access path crossing the driveway bridge is more than fifty (50) feet. Same as for Case II, except the gross vehicle weight considered shall be thirty thousand (30,000) pounds (AASHTO H15).

Wheel load:

Two (2) 12,000 lb. loads spaced five (5) feet apart.

Each concentrated load is to be placed upon any space a maximum of two and a half (2 ½) feet square.

May alternatively use AASHTO load distribution.

Uniform load:

One hundred (100) PSF with no allowable stress increase for duration of load. Live load reduction pursuant to Chapter 16 of the California Building Code.

Section 1602B.4 Case IV.

 Design Load for Private Residential Access Bridge Serving More than One Dwelling Unit or More than a Single Lot Fronting an Unimproved Street.

 Design loads shall be the same as for Case III in this chapter.

Section 1603B—Alterations or Repairs to Existing Driveway Bridges.

Section 1603B.1 Case V.

 Existing driveway bridges may need repairs as their structural system or moisture barrier system is often inadequate. Plans with the permit submittal, including concrete deck removal to install new deck waterproofing, for driveway bridge repairs should show the existing structural system for the driveway bridge so its adequacy to the design criteria of this Section may be checked.

 A structural evaluation by an architect or engineer of the structure based on the design load criteria of this chapter, as appropriate, shall be provided for any driveway bridge repair for a bridge that does not have documented structural calculations.

Section 1603B.2 Case VI.

 If there are practical constraints on accomplishing repair work to a bridge with a history of adequate performance, the following alternative minimum prescriptive requirements for driveway bridge repairs, when approved by the Building Official, may suffice in lieu of a structural evaluation pursuant to this chapter.

Section 1603B.2.1 Prescriptive Requirements for Repairs Necessary Due to Faulty Waterproofing Where there is Damage to Framing and Subfloor Around the Perimeter of the Driveway Deck, but, Framing and Subfloor Within the Field of the Deck has No Damage or has Only Minor Damage.

 These prescriptive requirements are as follows:

1.  Remove concrete, replace damaged framing and subfloor as necessary. Install flexible waterproof membrane. Three and one half inches (3½") to four inches (4") thick concrete replacement slab shall have No. 3 deformed steel reinforcement placed at four inches on center at center or slightly below center of slab and perpendicular to joist framing with similar reinforcement placed at six inches on center parallel to joist framing on top of perpendicular reinforcement. In lieu of reinforcing bar, steel fiber or glass fiber reinforced concrete may be used.

2.  If the existing driveway deck joist span is greater than ten (10) feet, a supplemental support wall shall be installed at approximately the center of the existing joist span. This support wall shall include a "T" foundation as for a two story conventional foundation and a minimum ½ inch plywood shear panel applied to the support wall on at least one side.

3.  Surface of concrete shall receive a concrete water sealant treatment in accordance with manufacturer's instructions.

4.  Existing structure and details for this work shall be shown on drawings and approved by the Building Official.

Section 1603B.2.2 Prescriptive Requirements for Repairs Necessary Due to Faulty Waterproofing Where there is Damage to Framing and Subfloor, and, the Existing Subfloor is to be Removed and Replaced.

 Since this repair will expose the joists, the existing deck framing can and shall be augmented. Prescriptive requirements for repairs shall be as follows:

1.  Remove concrete, replace damaged framing, and augment existing framing by doubling two inch thick framing at twelve inches or less on center or four inch thick framing at sixteen inches or less on center. 2x framing more than twelve inches on center and 4x framing more than sixteen inches on center shall be tripled to provide additional support.

2.  Replace damaged subfloor as necessary. Where 50% or more of the subfloor panels of the driveway deck are damaged and replaced, replace the damaged panels with minimum 1⅛" T&G plywood or minimum two layers of ¾" plywood subfloor. Additional plywood subfloor panels shall be added on top of the undamaged subfloor for a level subfloor.

3.  Install flexible membrane waterproofing in accordance with manufacturer's instructions. Hot mopped conventional waterproofing shall not be utilized unless specifically approved prior to installation by the Building Official.

4.  Three and one half inches (3½") to four inches (4") thick concrete replacement slab shall be reinforced with minimum No. 3 deformed steel reinforcement placed at four inches on center at center or slightly below center of slab and perpendicular to joist framing with similar reinforcement placed at six inches on center parallel to joist framing on top of perpendicular reinforcement. In lieu of reinforcing bar, steel fiber or glass fiber reinforced concrete may be used.

5.  If the existing driveway deck joist span is greater than 10 feet, a supplemental support wall shall be installed at approximately the center of the existing joist span. This support wall shall include a "T" foundation as for a two story conventional foundation and a minimum ½ inch plywood shear panel applied to the support wall on at least one side. Surface of concrete shall receive a concrete water sealant treatment in accordance with manufacturer's instructions.

6.  Existing structure and details for this work shall be shown on drawings and approved by the City.

Section 1604B—Wood Driveway Deck.

 Where a new wood subfloor deck is used it shall be a minimum of 2× T&G boards or 1⅛ inch minimum T&G plywood subfloor.

Section 1605B—Waterproof Membrane.

 A flexible membrane waterproofing shall be installed unless a solid inflexible substrate is provided for hot-mopped built-up waterproofing. The waterproofing membrane shall be suitable for the use intended and installed in accordance with the manufacturer's instructions.

Section 1606B—Public Right-Of-Way Encroachment.

The public right-of-way and any watercourse shall be clearly shown on the plans submitted for a permit. Any proposed or existing structure located within the public right-of-way and/or near a watercourse shall have an encroachment permit on file or one shall be issued, including appropriate fees, prior to building permit issuance. If the encroachment permit is denied, the proposed structure shall not be permitted.

Section 1607B—Zoning/Design Review.

If, as a result of alteration or repair work, the exterior appearance of any element of the structure, including guardrails, is proposed to be altered in such a way as to subject the project to Design Review, such changes shall first be approved by the Zoning Division.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.648 - CBC Section 1704.1 amended.

In Section 1704.1 of the California Building Code, replace Exception number 3 in its entirety with the following:

3.  The provisions of California Health and Safety Code Division 13, Part 6 and the California Code of Regulations, Title 25, Division 1, Chapter 3, commencing with Section 3000, shall apply to the construction and inspection of factory-built housing as defined in Health and Safety Code section 19971.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.649 - CBC Section 1704.4 amended.

In Section 1704.4 of the California Building Code, delete Exception number 4 in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.650 - CBC Section 1704.8 amended.

In Section 1704.8 of the California Building Code, add ."..and connecting grade beams" after "Driven deep foundations..." in the section title.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.651 - CBC Section 1704.9 amended.

In Section 1704.9 of the California Building Code, add ."..and connecting grade beams" after "Cast-in-place deep foundations..." in the section title and add ."..and connecting grade beams" after "Helical pile foundations..." in the section title.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.652 - CBC Section 1805.2.1 amended.

In Section 1805.2.1 of the California Building Code, delete "Where installed beneath the slab," in the first sentence of the second paragraph.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.653 - CBC Sections 1807.1.3 and 1807.1.4 deleted.

Delete Sections 1807.1.3 and 1807.1.4 of the California Building Code in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.654 - CBC Section 1807.1.6.1 amended.

In Section 1807.1.6.1 of the California Building Code, after ."..shall not be less than the thickness of the wall supported," insert "or 6," whichever is greater"

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.655 - CBC Section 1809.3 amended.

In Section 1809.3 of the California Building Code, replace the first sentence with "The top surface of footings, foundations, and grade beams shall be level."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.656 - CBC Sections 1809.8, 1809.9.2, 1809.11, and 1809.12 deleted.

Delete Sections 1809.8, 1809.9.2, 1809.11, and 1809.12 of the California Building Code in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.658 - CBC Section 1805.5 amended.

In Section 1805.5 of the California Building Code, delete Table 1807.1.6.3(1) in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.660 - Chapter 18B added.

Add the following new Chapter 18B for requirements for Grading, Excavations, and Fills:

Chapter 18B
GRADING, EXCAVATIONS, AND FILLS

Section 1801B—Definitions.

 The following words and phrases, wherever used in this chapter, shall be construed as defined in this section unless otherwise required by the context. The singular shall be taken to mean the plural, and the plural shall mean the singular when required by the context of this chapter.

 APPLICANT is the property owner and his authorized agents who apply for a Grading Permit pursuant to this chapter.

 BENCH is a relatively level surface interrupting the slope of an excavation or embankment in sloping natural ground or cut or fill surfaces.

 BUILDING PERMIT is a currently valid building permit issued by the City of Oakland.

 CITY is the City of Oakland.

 CITY COUNCIL is the City Council of the City of Oakland.

 CITY ENGINEER is the Deputy Director, Community and Economic Development Agency, and his or her successor in title.

 CITY ADMINISTRATOR is the City Administrator of the City of Oakland.

 CIVIL ENGINEER is an engineer currently possessing an active license issued by the State of California for the practice of civil engineering.

 CIVIL ENGINEER IN RESPONSIBLE CHARGE is that particular civil engineer whose signature appears on the initial Statement of the Engineer as submitted to the City with an application for a Grading Permit.

 CLEARING & GRUBBING is site preparation for grading or construction by mechanical or manual means consisting primarily of, but not limited to, the removal of vegetation.

 COMPACTION is the densification of fill by mechanical means.

 CUT SLOPE is a finished or interim surface of graded material caused by the removal of existing soils which exist naturally or as the result of previous filling, dumping or other method of placement.

 DIRECTOR OF CITY PLANNING is the Deputy Director, Community and Economic Development Agency, and his or her successor in title.

 ELEVATION is the vertical distance above City of Oakland datum.

 EROSION is the wearing away of ground surface due to natural action of the elements.

 EXCAVATION is cutting, digging or moving of earth, rock or similar materials and includes the conditions resulting therefrom.

 EXPANSIVE SOIL is those soils which are likely to cause damage to improvements such as streets, structures and buildings from their natural actions depending on water content.

 FILL is the depositing or placing of earth, rock or similar materials, from the same or different site, and includes the conditions resulting there from.

 GRADING is excavation or filling, or any combination thereof, and shall include the conditions resulting from any excavating or filling.

 GRADING PERMIT is a currently valid grading permit issued by the City of Oakland.

 HOLIDAY is New Year's Day, Martin Luther King Jr. Day, President's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day.

 LAND DISTURBANCE is any moving or removing of the soil mantle or top six inches of soil, whichever is shallower, by manual or mechanical means whether or not that soil is removed from the site, when the disturbed site area is greater than ten thousand (10,000) square feet measured horizontally, for all purposes except gardening or agriculture.

 LAND STABILITY PROBLEM AREA is any site where there is information available that indicates special consideration should be undertaken due to purported land stability problems on or in the vicinity of the site.

 NATURAL PLANTING is the planting of varieties of plants which will survive under the natural conditions of graded areas without regular irrigation and maintenance after establishment.

 PERMANENT EXCAVATION OR FILL is excavation or fill created other than as defined herein as "Temporary" excavation or fill.

 PERSON includes an individual, business and any other legally constituted entity such as, but not limited to, a limited partnership, limited liability company, and a corporation.

 PLANS are maps, sketches, profiles, construction drawings and specifications, or any combination thereof as required to adequately describe the work, all as prepared by a Civil Engineer, all in accordance with this Article. Plans shall also include grading plans, drainage plans, erosion control plans and sedimentation control plans.

 PROTECTED TREES shall be as defined in Chapter 12.36 of the Oakland Municipal Code.

 SEDIMENT is earth material deposited by water.

 SOILS REPORT is a report prepared by a Civil Engineer which shall include, but is not limited to, field test results and observations regarding the nature, distribution and strength of existing soils and recommendations and conclusions for grading procedures and design(s) for corrective action if necessary (including specifications for doing the work).

 SITE is all that contiguous parcel of land where grading is required to be accomplished under a permit.

 SLOPE is an inclined ground surface, the inclinations or rate of slope of which is expressed as a ratio of horizontal distance to vertical distance, or as a percentage using a ratio of vertical distance to horizontal distance.

 SUPERINTENDENT is the owner or that particular agent of the owner, who is fully responsible for the performance of the work required by this chapter.

 TEMPORARY EXCAVATION OR FILL is an excavation or fill created as a temporary condition to accommodate construction of a structure authorized by a valid building permit, and which will not remain after completion of the work.

 WATERCOURSE is a stream, stream bed, creek, canal, paved ditch, lake or other open drainage way as also defined in Chapter 9.16, Watercourses, of the Oakland Municipal Code.

 WET (OR RAINY) SEASON is October 15th until April 15th inclusive.

Section 1802B.1 Permit—When Required.

 No person shall do or cause any grading in private or public property without first having obtained a permit to do so from the City Engineer whenever such grading will result in any of the following:

1.  The volume of excavation or fill will exceed fifty (50) cubic yards provided either:

a.  the existing or the resulting rate of slope will exceed 20%; or

b.  the vertical distance between the top and bottom of excavation or fill will exceed five feet at any location.

2.  Any permanently unretained excavation or fill exceeding five cubic yards where the vertical distance between the top and bottom of the excavation or fill exceeds five feet at any location, disregarding benches; and the rate of slope of the surface exceeds 2 to 1 (2:1) for fill or 1.5 to 1 (1.5:1) for excavation, regardless of findings in the Soils Report.

3.  An excavation or fill exceeding five cubic yards within fifteen (15) horizontal feet of any property line if the bottom of such excavation is below a line descending at a rate of slope of 2 to 1 from the existing ground surface at such property line, or if the top of such fill is above a line ascending at a rate of two to one from such property line, regardless of the findings in the Soils Report.

4.  Grading in connection with a building, swimming pool, retaining wall or other structure where the vertical distance between top and bottom of the unretained slope will exceed five feet at any point, disregarding benches, when the cut slope exceeds 1.5 to 1 or the fill slope exceeds 2 to 1.

5.  Any retained or unretained excavation or fill of any volume and height where the City has information of purported land stability problems on or in the vicinity of the site (i.e., "Land Stability Problem Area").

6.  Any "Land Disturbance" where the rate of slope of the ground surface exceeds 20%. Grading of an emergency nature to safeguard life or property may be undertaken prior to the issuance of a Grading Permit.

7.  If a grading permit is not otherwise required, the necessity for a grading permit involving ground slopes 20% or less and greater than 10%, where a Grading Permit would be required if the ground slope were greater than 20%, will be determined, for cause, by the City Engineer or his duly authorized representative.

8.  The volume of excavation or fill will exceed five hundred (500) cubic yards on a parcel or contiguous parcels.

9.  Grading, clearing or grubbing, or land disturbance activity that otherwise does not require a grading permit involves an area of one acre or more.

 A separate permit shall be required for each non-contiguous site. One permit may cover both an excavation and a fill on the same site.

Section 1802B.1 Permit—When Not Required.

 No permit shall be required pursuant to this chapter for any of the following:

1.  Temporary excavations in a public street or public right-of-way for which a permit has been issued under Title 12 of the Oakland Municipal Code.

2.  Any public agency which has a reciprocity agreement with the City of Oakland pursuant to work under this chapter.

3.  An excavation below finished grade for a basement, footing, retaining wall, swimming pool or other structure authorized by a valid building or foundation permit, which excavation will be completely occupied by and retained by the structure, provided such excavation is conducted in accordance with the laws of the State of California relating to lateral support when the existing and finished ground slope will not exceed 10%.

4.  A fill above existing grade, which fill will be retained by the exterior wall of a building, a retaining wall, swimming pool or other structure authorized by a valid Building Permit when the existing and finished ground slope will not exceed 10%.

5.  Grading within a street to conform to elevations established by the City Engineer and for which a permit has been issued under the provision of Title 12 of the Oakland Municipal Code.

6.  For test trenches, pits and borings done under the supervision of a Civil Engineer or Registered Geologist or Certified Engineering Geologist in accordance with the applicable regulations of the City of Oakland and the State of California.

7.  Cemetery graves.

8.  Water wells.

9.  For work to be done under the Surface Mining and Quarrying Ordinance of the Oakland Municipal Code.

10.  Gardening and agriculture.

Section 1802B.3 Permit—Items to Include in Application.

 The application for a Grading Permit must include all of the following items in triplicate:

1.  Application Form.

2.  Vicinity Map, Site Map and Grading Plan.

3.  Erosion and Sedimentation Control Plan, where required by the City Engineer.

4.  Statement(s) of the Civil Engineer(s) in Responsible Charge.

5.  Soils Report.

6.  A landscape addendum to the erosion and sediment control plans by a licensed landscape architect when required by the Director of City Planning.

7.  Proposed work schedule.

8.  Deposit for review of the application in accordance with the current master fee schedule.

9.  Itemized estimate of cost of work by a Civil Engineer.

10.  Such other items as may be required by the City Engineer his duly authorized representative to aid in the understanding and review of the proposed grading work.

11.  Proposed Dust Control Measures.

Section 1802B.4 Permit—Application Form.

 The following information is required on the application form:

1.  A description of the property in sufficient detail to permit its identification and general location.

2.  The name(s) and address(es) and phone number(s) of the owner or owners of the property.

3.  The reason for the grading.

4.  Whether the grading is for the purpose of preparing the site for a subdivision under the provisions of the California Subdivision Map Act and Title 16 of the Oakland Municipal Code.

5.  The name, address, telephone number and contractor's license number of the person or firm who will be doing the grading.

6.  The names, addresses, and registration numbers of the Civil Engineer(s) in Responsible Charge who will direct the work, who prepared the grading plans and who will provide the testing and inspection of the work.

7.  The amount in cubic yards of the proposed excavation and fill and the amount of the cumulative total of grading work.

8.  The equipment and methods to be used in the work.

9.  Whether any material will be hauled from or imported onto the site over public streets, and if so, the site from which or to which said material will be moved and the routes to be used.

10.  The approximate starting and completion dates of the work to be covered by the Grading Permit.

11.  An estimate of total cost of all work covered by the application.

12.  Whether the grading is located within the Special Studies Zone, Seismic Hazard Zone, Flood Hazard Area, watercourse, or Land Stability Problem Area or a site containing expansive soils.

13.  The signature of the owner or his authorized agent and the date of the application.

Section 1802B.5 Permit Application—Vicinity Map.

 The vicinity map shall show the project site in relationship to the surrounding area's watercourses, water bodies and other significant geographic features, roads and other significant structures.

Section 1802B.6 Permit Application—Site Map Anti Grading Plan

 The site map and grading plan shall be prepared by a Civil Engineer, are subject to approval of the City Engineer, and shall include all of the following:

1.  A topographic and boundary survey of the site, as provided in Section 15.04.140 of this Code, for all sites to be graded containing up to and including five acres. Sites containing more than five acres shall have contours at intervals and a minimum scale subject to the approval of the City Engineer. Enough off-site contours shall be included to show how surface runoff of storm water will flow on to and off the site.

2.  Proposed limits of cuts and fills, both temporary and permanent, and other earthwork clearly designated.

3.  Proposed retaining structures.

4.  Drainage Plan: to include existing, temporary, and final drainage facilities which shall be coordinated with erosion and sediment control plans. Supporting hydrology and hydraulic calculations for on-site and downstream systems shall be submitted when required.

5.  Existing and proposed improvements to the site.

6.  Existing off-site structures within fifteen feet of the site boundary and other off-site improvements which may be affected by the grading work.

7.  Public and private easements of record.

8.  A Soils Report, as hereinbefore defined, prepared by a registered design professional.

9.  Typical sections of areas to be graded and profiles of all proposed traveled ways for vehicles and pedestrians.

10.  Measures to be taken to protect against potential hazards arising during the progress of the grading work.

11.  If the site is in the Special Studies Zone, the plan shall show any purported fault trace which may or does cross or affect the site to be graded.

12.  All proposed corrective actions to be taken to alleviate existing site conditions detrimental to the improvements proposed including expansive soils, land stability problems, and seismic liquefaction and landslide.

13.  The location of the base and diameter at breast height of all protected trees, and indication as to which protected trees, if any, may be subject to removal or damage during construction per Chapter 12.36 of the Oakland Municipal Code.

14.  Any such additional items as required by the City Engineer to clarify or provide additional information which may be necessary to allow a complete review of the proposed work.

Section 1802B.7 Permit Application—Erosion and Sedimentation Control Plans.

 Erosion Control and Sedimentation Control Plans shall be prepared by a Civil Engineer, are subject to approval of the City Engineer, and shall include all of the following:

1.  Interim Measures. The plans shall include interim erosion and sedimentation control measures to be taken during wet seasons until permanent erosion and sedimentation control measures can adequately minimize erosion, excessive storm water runoff and sedimentation measures.

The plans shall include all necessary measures to be taken to prevent excessive storm water runoff or carrying by storm water runoff of solid materials on to lands of adjacent property owners, public streets, or to watercourses as a result of conditions created by grading operations.

The plan shall include, but not be limited to, such measures as short-term erosion control planting, waterproof slope covering, check dams, interceptor ditches, benches, storm drains, dissipation structures, diversion dikes, retarding berms and barriers, devices to trap, store and filter out sediment, and storm water retention basins. Off-site work by the Applicant may be necessary. The Applicant shall provide any off-site permission or easements necessary to present written proof thereof to the City Engineer. Erosion control work and sediment control work shall be coordinated with the grading work. A narrative description shall also be provided of measures to be taken, planting materials and specifications, and maintenance provision.

There shall be a clear notation that the plans are subject to changes as changing conditions occur. Calculations of anticipated storm water runoff and sediment volumes shall be included, if required by the City Engineer.

2.  Permanent Measures. The plans shall include permanent erosion and sedimentation control measures which shall be primarily oriented towards prevention of erosion and shall include, but not be limited to, such measures as permanent erosion control planting, paved ditches, planted swales, benches, storm drains, dissipation structures, rip rap, and storm water retention basins.

A narrative description shall also be provided of measures to be taken, specifications for planting materials, fertilizers, planting and maintenance procedures.

An estimate of the length of time which will be required for the planting to produce a permanent coverage which will be sufficient to provide the degree of erosion control protection for which it is designed.

Section 1802B.8 Permit Application Initial Statement(s) of the Civil Engineer(s) in Responsible Charge.

1.  One Civil Engineer in Responsible Charge. Where one Civil Engineer will be in responsible charge of the entire grading project, including, but not limited to the preparation of the grading plans, the exact following Initial Statement of the Engineer is required:

DATE

City Engineer

City of Oakland

Dalziel Administration Building

250 Frank Ogawa Plaza

Oakland, CA 94612

RE: Grading at (Same address as on application)

INITIAL STATEMENT OF THE ENGINEER

I have been retained by ____________(Applicant) to be in responsible charge of the grading work at property referenced above. I will assume full responsibility, as responsibility is defined in Section 15.04.660 of the Oakland Municipal Code, for carrying out the following to the best of my knowledge and ability:

a.  Assuring that testing and inspection required for the work in progress and the completed work shall be accomplished in a timely and professional manner to determine whether all the work is being/was done in accordance with plans, schedule and specifications approved by the City Engineer.

b.  Notifying the Applicant, verbally and in writing (with a copy to the City Engineer), of any work not being performed in accordance with the approved plans, schedule and specifications.

c.  Notifying the Applicant, verbally and in writing (with a copy to the City Engineer), of any work not meeting the requirements of the approved plans and specifications.

d.  Notifying the Applicant, verbally and in writing, of the modifications(s) required in his performance and the necessary corrective measures to be taken to cure all deficiencies.

e.  Submitting an amended grading plan (through the Applicant) to the City Engineer for his review and approval for any significant changes caused by unforeseen conditions, along with a report setting forth the reasons for these changes and the recommended changes to the improvement plans necessitated by the amendments to the grading plan.

f.  Notifying the Applicant, verbally and in writing (with a copy to the City Engineer), of any portion of the grading work affected by the amended plans and shall recommend whether or not the Applicant should proceed with the work before the amended plans are approved by the City Engineer.

g.  Submitting in a timely manner upon the Applicant's satisfactory completion of the work under the permit, a Statement of Completion with the results of all tests and inspections attached thereto.

h.  Stating in writing, along with the Statement of Completion, that the interim erosion control and sediment control measures appear to be adequate if properly maintained until the permanent erosion control measures are fully established, if any are required.

If my services on the job are terminated, I will, at said time of termination, submit to the City Engineer a Statement of Partial Completion addressing the progress and conditions of all of the applicable items above and attach thereto the results of such inspections and tests which have been completed.

Signed:

____________

(Registered Civil Engineer)

License No. ____________

Expiration ____________

2.  Multiple Responsibility. When the Civil Engineer in Responsible Charge is other than the Civil Engineer who prepared the approved grading plan, the following paragraph will be added to the letter in Item (1) above:

"I have examined the plans to be used for this work as prepared by (name and registration of Civil Engineer) dated and hereby approve and adopt them as to the portions concerning the work to be performed under this permit."

3.  Divided Responsibility. Where more than one Civil Engineer shall function as Civil Engineer in Responsible Charge and divide their responsibilities, each will submit in the exact text, the following Initial Statement of the Engineer:

DATE

City Engineer

City of Oakland

Dalziel Administration Building

250 Frank Ogawa Plaza

Oakland, CA 94612

RE: Grading at (Same address as on application)

INITIAL STATEMENT OF THE ENGINEER (DIVIDED RESPONSIBILITY)

I have been retained by ____________ (Applicant) to be in responsible charge of the portions of grading work enumerated below. I will assume full responsibility for carrying out the following to the best of my knowledge and ability (Each individual engineer shall enumerate and provide the portions of work he is to be responsible for).

If my services on the job are terminated, I will, at said time of termination, submit to the City Engineer a Statement of Partial Completion addressing the progress and conditions of all of the applicable items above and attach thereto the results of such inspections and tests which have been completed.

Signed:

____________

(Registered Civil Engineer)

License No. ____________

Expiration ____________

4.  When those Civil Engineers in Responsible Charge, as specified in Item 3 above, are not the Civil Engineer who prepared the approved plan, each Civil Engineer in Responsible Charge shall add the paragraph shown in Item 2 above.

5.  No Initial Statement(s) of the Engineer shall be accepted as complete until all responsibilities addressed in Item 1 above have been covered by one or more Civil Engineer(s) in Responsible Charge.

Section 1802B.9 Permit Application: Initial Statement(s) of the Civil Engineer(s) in Responsible Charge—Responsibilities Defined.

 The responsibilities of the Civil Engineer(s) in Responsible Charge defined for purposes of this Article are defined as follows:

1.  Inspection and Testing. The Civil Engineer in Responsible Charge shall inspect the work in progress and perform such tests as may be necessary during the progress of the work to determine whether all grading work is done in accordance with the Plans and Specifications approved by the City Engineer. The City Engineer or his authorized representative may conduct unscheduled inspections of grading work in progress to assess whether such work poses a hazard to life and public or private property.

2.  Substandard Performance; Notification of Applicant. When the inspection and testing reveals that the work is not being properly performed, and/or all or any portion of the work does not meet with the requirements of the approved Plans, Schedule and Specifications, the Civil Engineer in Responsible Charge shall immediately notify the Applicant, verbally and in writing (with a copy to the City Engineer). The Civil Engineer in Responsible Charge shall also notify the Applicant of any modifications which are required in his performance and the necessary corrective measures to be taken to cure the deficiencies in the work.

3.  Changes in the Approved Plans, Schedule and Specifications Due to Unforeseen Conditions. If, during the progress of the grading work, the Civil Engineer in Responsible Charge finds it necessary to require significant changes due to unforeseen conditions, he shall submit (through the Applicant), amended Plans, Schedule and Specifications for the approval of the City Engineer. He shall also submit, at that time, a report setting forth the reason for the changes. The report shall also include any recommended changes to future improvement plans necessitated by the amended plan. The Civil Engineer in Responsible Charge shall also notify, verbally and in writing (with a copy to the City Engineer), the Applicant of any portion of the grading work affected by the amended plans and recommended whether or not work should proceed before the amended plans are approved by the City Engineer.

4.  Upon completion of the grading work, the Civil Engineer in Responsible Charge shall submit in a timely manner a Statement of Completion. He or she shall, at that time, also state in writing that interim erosion and sedimentation control measures, where required by the City Engineer, have been taken and appear to be adequate until permanent erosion control planting is effectively established.

5.  It shall not be the responsibility of the Civil Engineer in Responsible Charge to perform the direction or supervision of the personnel and equipment performing the actual grading work unless they are in the employ of the Civil Engineer in Responsible Charge.

6.  It shall not be the responsibility of the Civil Engineer in Responsible Charge to supervise, direct, inspect, or test any improvements being constructed coincidentally with the grading work but not a part of the approved grading plan.

Section 1802B.10 Permit Application—Proposed Work Schedule.

 The Applicant must submit a master work schedule showing the following information:

1.  Proposed grading schedule.

2.  Proposed conditions of the site on each July 15, August 15, September 15, October 1, and October 15, during which the permit is in effect.

3.  Proposed schedule for installation of all interim drainage, erosion and sediment control measures including, but not limited to the stage of completion of erosion and sediment control devices and vegetative measures on each of the dates set forth in Subsection 2 above.

4.  Schedule for construction of final improvements, if any.

5.  Schedule for installation of permanent erosion and sediment control devices where required.

Section 1802B.11 Permit Application Itemized Estimate of Cost of Work by Civil Engineer.

 Quantities and costs of all the work to be done under the Grading Permit shall be submitted by a Civil Engineer to aid in establishing values for security deposits or surety bonds which may be required. The actual value of security shall be determined by the City Engineer.

Section 1802B.12 Permit Application—Related to Special Studies Zones And Seismic Hazard Zones Designated by State Geologist (Geologic Report).

 No Grading Permit shall be issued for any site in the Special Studies Zones or Seismic Hazard Zones designated by the State Geologist before a Geologic Report has been submitted and approved pursuant to the requirements of Chapter 15.20 of the Oakland Municipal Code. Said report and review shall be submitted as a part of the application for Grading Permit along with all other material required by this chapter.

Section 1802B.13 Permit Application—Related to Flood Hazard Area.

 No Grading Permit shall be issued for any site located in a designated Flood Hazard Area unless the grading plan provides for mitigation measures relative to the projected flood hazard. The mitigation methods are subject to the review and approval of the City Engineer.

Section 1802B.14 Permit Application—Related to Expansive Soils Conditions.

 No Grading Permit shall be issued for any site which is underlain by expansive soils unless the grading plan includes mitigation measures to prevent structural damages which may be caused by conditions due to expansive soils.

Section 1802B.15 Permit Application—Dust Control Measures.

 "Best Management Practices," as developed by the City Engineer or an appropriate reference approved by the City Engineer, shall be used throughout all phases of construction. This includes any suspension of work, alleviation or prevention of any fugitive dust nuisance and the discharge of smoke or any other air contaminants into the atmosphere in such quantity as will violate any City of Oakland or regional air pollution control rules, regulations, ordinances, or statutes.

 Water, dust palliatives or combinations of both shall be applied continuously and in sufficient quantity during the performance of work and at other times as required. Dust nuisance shall also be abated by cleaning, vacuuming and sweeping or other means as necessary.

 A Dust Control Plan may be required as a condition of permit issuance or at other times as deemed necessary to assure compliance with this section. Failure to control effectively or abate fugitive dust nuisance or the discharge of smoke or any other air contaminants into the atmosphere may result in suspension or revocation of the permit, in addition to any other applicable enforcement actions or remedies.

Section 1802B.16 Permit Application—Soils Report Contents.

 All Soils Reports shall be based, at least in part, on information obtained from on-site testing. The minimum contents of a Soils Report submitted pursuant to this chapter shall be as follows:

1.  Logs of borings and/or profiles of test pits and trenches.

a.  Borings:

i.  The minimum number of borings acceptable, when not used in combination with test pits or trenches, shall be two, when in the opinion of the Soils Engineer such boring shall be sufficient to establish a soils profile suitable for the design of all footings, foundations and retaining structures.

ii.  The depth of each boring shall be sufficient to provide adequate design criteria for all proposed structures.

iii.  All boring logs shall be included in the soils report.

b.  Test Pits and Trenches:

i.  Test pits and trenches shall be of sufficient length and depth to establish a suitable soils profile for the design of all proposed structures.

ii.  Soils profiles of all test pits and trenches shall be included in the soils report.

2.  A plat shall be included which shows the relationship of all borings, test pits and trenches to the exterior boundary of the site. The plat shall also show the location of all proposed site improvements. All proposed improvements shall be labeled.

3.  Copies of all data generated by field and/or laboratory testing to determine allowable soil bearing pressures, shear strength, active and passive pressures, maximum allowable slopes where applicable and any such other information which may be required for the proper design of foundations, retaining walls and other structures to be erected subsequent to or concurrent with work done under the Grading Permit.

4.  A written report which shall include, but is not limited to the following:

a.  Site description.

b.  Local and site geology.

c.  Review of previous field and laboratory investigations on the site, if any.

d.  Review of information on or in the vicinity of the site on file with the City Engineer, if any.

5.  Site stability shall be addressed with particular attention to existing conditions and proposed corrective actions at locations where land stability problems exist.

6.  Conclusions and recommendations for foundations and retaining structures, resistance to lateral loading, slopes and specifications for fills and pavement design as required.

7.  Conclusions and recommendations for temporary and permanent erosion control and drainage. If not provided in a separate report they shall be appended to the required soils report.

8.  All other items which the Soils Engineer deems necessary.

9.  The signature and registration number of the Civil Engineer preparing the report.

10.  When the certification date by the Soils Engineer in Responsible Charge is more than three years old, the soils report be re-certified, or a new soils report shall be provided.

Section 1802B.17 Permit Application Referred to City Planning.

 All applications for Grading Permits shall be referred to City Planning. City Planning shall report on any aspect of the proposed grading, excavation, or fill that relates to or affects the Oakland General Plan, and District or Area Plan, the zoning and subdivision regulations of the City, the preservation of natural scenic character, and any other environmental requirements, including the requirements of the California Environmental Quality Act.

Section 1802B.18 Permit Application Referred to City Planning Landscape Addendum to the Grading Plans.

 A Landscape Addendum to the Grading Plans may be required at the discretion of City Planning. The landscaping plan, when required, shall be prepared by a licensed Landscape Architect to the current professional standards in landscape architecture and is subject to the approval of City Planning.

Section 1803B Report of City Planning—Time Limit for Review.

 City Planning, upon completion of its investigation including review of the Landscape Addendum (when required) shall transmit its report and recommendations to the City Engineer and no permit shall be issued until such report has been received.

Section 1804B Permit—Conditions Upon Issuance.

 In granting any permit under this chapter, the City Engineer may attach such conditions thereto as he deems reasonably necessary to safeguard life, public and private property, and to ensure that the work will be carried out in an orderly manner in conformance with all regulations and without creating a public nuisance; and he/she may add to, remove, or change such conditions from time to time during the duration of the permit as he/she deems reasonably necessary as a result of changed conditions or otherwise. Such conditions may include, but shall not be limited to:

1.  Limitations on the hours of operations, days of operations or the portion of the year in which the work may be performed.

2.  Restrictions as to the size and type of equipment to be used.

3.  Prohibition or restriction on the use of explosives.

4.  Designation of the routes over which the materials may be transported.

5.  Requirements as to the suppression of dust and prevention against spilling or tracking of dirt, and the prevention of excessive noise or other results offensive or injurious to the neighborhood and the general public, or any portion thereof.

6.  Regulations as to the use of public streets and places in the course of the work.

7.  Regulations for the repair and cleaning of streets and other public facilities if their safe, operable, and clean condition has been jeopardized.

8.  Requirements for safe and adequate drainage of the site.

9.  A requirement that approval of the City Engineer be secured before any work which has been commenced, may be discontinued.

10.  A requirement that personnel and equipment be provided at the site during storms to prevent damage to other property from flooding or the depositing of material washed from the site.

11.  Requirements for fences, barricades or other protective devices.

12.  Requirements pertaining to reshaping and planting the site, including the time limit for such work.

Section 1805B.1 Statement of Completion of Civil Engineer(s) in Responsible Charge - Final Completion.

 Within fourteen (14) calendar days after completion of the work authorized by the Grading Permit, the Civil Engineer(s) in Responsible Charge shall provide the following Statement of Completion in his/her areas of responsibility with respect to the Grading Permit in writing. The grading work under any permit shall not be considered complete until each of the following items have been addressed by the Civil Engineer in Responsible Charge, who shall file with City Engineer a written statement stating that said items have been completed and/or are true to the best of his/her knowledge and belief:

1.  Her/his/their appropriate portion of grading work has been done in accordance with the plans and amended plans prepared or adjusted by her/him and approved by the City Engineer. All modifications made by the Civil Engineer in Responsible Charge shall be specifically set forth in the Statement of Completion.

2.  In the Civil Engineer's opinion, the finish graded slopes in the subject area are in a stable condition.

3.  Where required by the City Engineer, interim and/or permanent erosion and sedimentation control measures have been taken, and that where interim measures have been taken, they will adequately control erosion and sedimentation if properly maintained, until permanent erosion control planting is effectively established.

4.  The magnitude of the total settlements and differential settlements which are likely to occur, the allowable loads of bearing pressures which may be imposed, and stating that compaction is adequate for the uses proposed for the property and adequate to develop the recommended bearing pressures.

5.  Any limitations which should be imposed on the development of the property because of soil conditions and amendments to the approved grading plan.

6.  The Civil Engineer(s) in Responsible Charge shall also submit with the above items, all documentation necessary to support her/his/their Statement(s) of Completion (i.e., records of inspections, tests, observations, etc.).

Section 1805B.2 Statement of Completion of Civil Engineer(s) in Responsible Charge Partial Completion.

 When, in the estimation of the City Engineer, an entire grading project cannot be completed before phased construction may proceed on structural foundations or retaining structures in order to provide for the public and private welfare, safety and convenience, the City Engineer may require the Civil Engineer in Responsible Charge to submit a partial written statement addressing the satisfactory completion of those items. Separate building permits shall be required for the necessary structures. The total grading work shall be addressed in Statement of Completion prior to final inspection of any structures.

Section 1805B.3 Statement of Completion of Civil Engineer(s) in Responsible Charge—Responsibility Changes Hands.

 In all grading operations, if one Civil Engineer in Responsible Charge's services are terminated and another Civil Engineer in Responsible Charge assumes the responsibility for the remainder of the work, each Civil Engineer shall immediately file the Statement of Completion with respect to the portion of the work for which she/he is responsible and stating what work was completed and what work was improperly or inadequately done at the time of the termination of her/his responsibility. No grading work shall proceed unless the Civil Engineer in Responsible Charge takes the responsibilities, and the City Engineer shall suspend any permit when the grading work is not under the responsibility of a Civil Engineer in Responsible Charge approved by the City.

Section 1805B.4 Statement of Completion of Civil Engineer(s) in Responsible Charge—Grounds for Denial of Building Permit.

 When a Grading Permit is issued on a site, the Building Official shall be notified that no Building Permit for the construction or repair of any structure on the property shall be issued until Statement(s) of Completion covering the completed grading work has/have been filed, unless the issuance of a Building Permit is required to allow construction of retaining walls or other structures designed in accordance with the Oakland Building Construction Code in order to allow completion of the grading work, in which case a cash bond may be required to guarantee the filing of Statement(s) of Completion covering the completed grading work.

Section 1805B.5 Statement of Completion of the Civil Engineer(s) in Responsible Charge—Related to Final Inspection and Certification of Occupancy.

 No Final Inspection, as required by the Oakland Building Construction Code, shall be made and no Temporary Certificate of Occupancy or Certification of Occupancy shall be issued by the Building Official for any structures located on a site for which a Grading Permit has been issued prior to the acceptance by the City Engineer of the Statement of Completion of the Civil Engineer in Responsible Charge. The City Engineer may reject a Statement of Completion which, in her/his judgment, does not adequately meet the requirements of this chapter.

Section 1806B Responsibility for Performance of Grading Work.

 The Permittee shall bear full responsibility for the performance and maintenance of the work in accordance with the approved Plans, Schedule, Conditions and Specifications and any approved modifications thereof, and also shall bear full responsibility for accomplishing the work in accordance with the recommendations of the Civil Engineer in Responsible Charge during the progress of the work. The Permittee shall be present at all times work is in progress and shall be completely responsible for the supervision and direction of all personnel and equipment performing work under the Grading Permit.

Section 1807B Applications and Permits—Time of Validity.

1.  Applications for grading permits shall expire 180 days after the date of application. One extension of the application may be requested for not more than 180 additional days (one year total from the date of application). Fees as established in the master fee schedule shall be paid at the time of application submittal and extension request.

2.  Grading permits shall expire when the work has not commenced within 180 days from the date of issuance of the grading permit or when the work has not been completed within one year following the date of commencement.

3.  No grading work shall occur during the grading moratorium (wet season). Temporary shoring or permanent retaining structures shall be installed before commencement of the grading moratorium (wet season). The Civil Engineer in Responsible Charge shall show what actions will be implemented to eliminate any dangerous conditions which may result from the incomplete grading work, or shall state no such actions are necessary. The addendum shall bear the Civil Engineer's signature and registration number.

Section 1808B Grounds for Denial—Hazard.

 The City Engineer shall deny a permit for any violation of this Code, other laws, rules and regulations in effect in the City, or whenever, in her/his judgment, the proposed work will directly or indirectly create a hazard to human life or endanger public or private property. If, in the opinion of the City Engineer, the danger or hazard can be eliminated by the erection or installation of protective devices or by performing the work in a particular manner approved by the City Engineer, the City Engineer may grant a permit upon conditions that the protective and precautionary work or manner of performing the work, as approved, shall be used.

Section 1809B Grounds for Denial—Disinterested Civil Engineer in Responsible Charge.

 In all cases where a Grading Permit is required, to prevent potential conflicts of interest and to assure that inspection and testing of the grading work is performed by a disinterested party, neither the owner of the property nor the builder who is to construct the improvements on the property or perform the grading work, shall be the "Civil Engineer in Responsible Charge" that provides any "Statement of Engineer" pursuant to the requirements of this chapter.

Section 1810B General Requirements Applicable for All Grading Work Unless Modified by the City Engineer.

 The following shall apply to all grading work:

1.  Grading, erosion control and sedimentation control work shall be done in accordance with plans hereinbefore described.

2.  No grading work shall be done during the wet season except for emergency stabilization of geotechnical instability.

3.  Temporary erosion and sedimentation control facilities shall be completely in place prior to October 15th, and shall be diligently maintained to ensure effectiveness through April 15th.

4.  The hours of grading operations shall be only between 7:00 a.m. to 9:00 p.m. weekdays, 8:30 a.m. to 6:00 p.m. Saturdays, and prohibited on Sundays and Holidays unless otherwise approved by the City Engineer. Exceptions will only be granted if it can be shown that there is a compelling public interest to grade during prohibited times.

5.  No clearing and grubbing shall take place on any site for which a Grading Permit is required prior to the issuance of a valid Grading Permit.

6.  Where required, a valid Tree Removal Permit must be obtained prior to the issuance of a Grading Permit. No tree removal shall take place until both Tree Removal Permit and a Grading Permit, if required, has been issued.

7.  No grading shall be approved on properties adjacent to the site without the written permission of the adjacent property owner. Such written permission shall be notarized and acknowledged and presented to the City Engineer as a part of the items required with the application for a Grading Permit.

8.  The rate of slope of the surface of permanent fills shall not be steeper than 2 to 1 and the rate of permanent cut slopes shall not be steeper than 1.5 to 1, unless otherwise recommended in the Soils Report and approved by the City Engineer.

9.  Areas to receive fill shall be adequately prepared by stripping unsuitable material and by benching slopes. Where past sliding is known or suspected or where unstable material exists, all such unstable material shall be stripped, with slip surfaces destroyed by benching and subdrainage installed before the fill is placed.

10.  Drainage facilities shall be provided to convey stormwater to a natural watercourse, swale or other drainage way, or to a public storm drainage system at locations and in a manner satisfactory to the City Engineer. Adequate temporary measures shall be taken to control stormwater during grading operations.

11.  Erosion control shall include planting of all graded areas to be left exposed to the elements in accordance with the planned maintenance of such areas.

12.  No grading shall be done which will cause sloughing of materials from or onto adjoining property.

Section 1811B.1 Security—Grading Performance.

 A performance security shall be required for every grading permit issued under this chapter. A minimum of one thousand dollars ($1,000) or two percent (2%) of the Civil Engineer's estimate of cost of grading work, whichever is greater, shall be provided in cash or cashier's check. The total amount of the security shall be determined by the City Engineer after consideration of the estimated cost of the work, the possible consequences of non-completion, particularly with respect to adjacent properties, public safety and any other relevant factors. The minimum security required shall be one hundred percent (100%) of the engineer's estimate of cost of grading work. The form of the security shall be cash, cashier's check, approved surety bond (for an indefinite duration), irrevocable letter of credit, or other liquid financial instrument approved by the City Engineer.

 The security shall remain in full force and effect until the Statement of Completion has been accepted by the City Engineer. The security shall obligate the principal, his or her executors, administrators, successors and assigns, jointly and severally, with the surety, and shall inure to the benefit of the City and to any person aggrieved by the principal's (owner/applicant's) failure to comply with the conditions thereof.

 The security shall be conditioned on the faithful performance of the work under the Grading Permit and the immediate abatement of the hazards above-named. Failure of the person to whom the permit is issued to abate such hazard(s) in a timely manner shall result in Summary Abatement.

Section 1811B.2 Security—Erosion and Sedimentation Control Performance.

 Where erosion and sedimentation control work is required as a part of the approved grading plan, the City Engineer may require such work to be secured either separately from, or along with, any grading security which may be required.

 The Erosion and Sedimentation Control security shall be conditioned on the performance of the erosion and sedimentation control portion of the approved grading plan and shall remain in full force and effect during the "Wet Season" or such other time period which shall be determined by the City Engineer.

Section 1811B.3 Security—Term and Completion.

 The term of each security shall begin upon the date of the posting thereof and shall end upon the completion to the satisfaction of the City Engineer of all of the terms and conditions of the permit for the work. Such completion shall be evidenced by a statement thereof signed by the City Engineer.

Section 1812B.1 Notice of Default—General.

 Whenever the City Engineer finds that a default has occurred in the performance of any term of condition of any permit, written notice thereof shall be given to the contractor, property owner, and the surety of the security. Such notice shall state the work to be done and the period of time deemed by the City Engineer to be reasonably necessary for the completion of the work.

 The Owner shall have fourteen (14) calendar days from the date of service of the Notice of Default to comply with same or to appeal to the Hearing Examiner. In an emergency, the City Engineer shall have the authority to take action three calendar days after service of the Notice, and to use liquid funds of the security to initiate remediation actions.

Section 1812B.2 Notice of Default—Duty of Surety.

 After fourteen (14) calendar days from the date of service of a Notice of Default, the surety shall cause the required work to be performed expeditiously and within the time therein specified or, failing therein, pay to the City the estimated cost of completing the work, as determined by the City Engineer, but not to exceed the principal sum of the security.

Section 1812B.3 Notice of Default—Right of Entry.

 In the event of any default in the performance of any term or condition of the permit for the work, the surety or any person employed or engaged on his behalf shall have the right to enter upon the premises to complete the required work or make it safe. Representatives of the City shall have the right to enter upon the premises during the course of the work or upon completion to check for compliance with the terms or conditions of the permit and the provisions of this chapter.

Section 1812B.4 Notice of Default—Performance Interference Prohibited.

 No person shall interfere with or obstruct the ingress or egress to or from any such premises by an authorized representative or agent of any surety or of the City engaged in completing the work required to be performed under the permit, checking on compliance of the work with the terms or conditions of the permit and the provisions of this chapter, or taking emergency actions deemed necessary for the protection of the public and adjoining properties.

Section 1813B Violation and Abatement.

 Violations of this chapter shall be abated by the City and costs, fees, penalties, and accruing interest for abatement shall be assessed by the City and collected in accordance with the provisions of Chapters 1.08, 1.12, and 15.08 of the Oakland Municipal Code.

Section 1814B Erosion and Sedimentation Control.

Section 1814B.1 Responsibility for Preventive Measures to Control Erosion and Sedimentation.

 Any person who performs grading, clearing and grubbing or other activities that disturb the existing soil shall take appropriate preventative measures to control erosion, sedimentation of eroded materials onto adjacent lands, public streets or rights-of-way, or carrying of eroded materials to any watercourse by any route. The person in possession and the owner of the property on which the soil is disturbed are responsible to perform necessary preventative measures to control erosion and sedimentation.

Section 1814B.2 Preventative Measures to Control Erosion and Sedimentation.

 Preventative measures shall be those prescribed in the "Manual of Standards for Erosion and Sediment Control Measures" of the Association of Bay Area Governments and as subsequently amended. Preventative measures shall include both interim and permanent measures to control erosion and sedimentation.

 Interim preventative measures shall be taken during the period October 15 to April 15 until permanent control measures are complete and effective. Interim measures shall include, but not be limited to, waterproof slope covering, drainage ditches around slopes, short-term control planting, slope benching, rip-rap, storm drains and energy dissipation structures.

 Permanent preventative measures shall include, but not be limited to, completion of buildings, walls or other structures, permanent planting, paved ditches, slope benching, rip-rap storm drains, paving and energy dissipation structures.

 The City Engineer may require an erosion and sedimentation control plan prior to issuance of any building permit on lots where the conditions of lot location, configuration or contour may result in increased problems of erosion or sedimentation control.

Section 1814B.3 Classification of Erosion and Sedimentation Conditions as Constituting a Hazard.

 Any grading, clearing and grubbing or other activities that disturb the existing soil so that erosion, sedimentation of eroded materials onto adjacent lands, public streets or rights-of-way or carrying of eroded materials to any watercourse occurs, such activities shall constitute an dangerous condition and shall be abated as set forth in this chapter.

Section 1815B Discharge of Concentrated Flow.

Section 1815B.1 General.

 Except as established in this Section, it shall be unlawful for anyone to discharge or channel concentrated flow of storm water onto neighboring property.

Section 1815B.2 Methods.

 Approved methods of discharge may be achieved in the following ways:

1.  Drain to Streets. For property located on an improved street which abuts the property frontage, storm water may drain to the public right-of-way when directed under the sidewalk in accordance with the Oakland Municipal Code. If the property is located on an unimproved street, the property owner shall submit, for approval by the City Engineer, a detail showing how storm water discharges to the street. The drainage detail shall show the size and type of conduits, the points where conduit day-lights on the slope, and the type and location of slope protection.

2.  Dissipation of Storm Water within the Property Boundaries. The dissipater system shall be designed by a Civil Engineer and shall not be closer than fifteen (15) feet from a property line. The system shall be approved by the City Engineer prior to construction. A Special Inspection letter shall be submitted to the City Engineer and approved prior to issuance of a Temporary Certificate of Occupancy or a Certificate of Occupancy.

3.  Pumping of Storm Water to a City Approved Means of Disposal. Storm water may be collected in a catch basin and discharged by a pump to the street surface.

4.  Discharging Storm Water to a Public Storm Sewer System. The connection shall be designed by a licensed professional and approved by the City Engineer. A permit issued by the Building Official for direct connection to the public storm sewer system shall be required. Granting of such permit shall be a discretionary action.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.662 - CBC Section 1908.1.8 amended.

In Section 1908.1.8 of the California Building Code, delete subsection (a) in its entirety and delete the exceptions to subsection (b) and subsection (c) in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.664 - CBC Section 1909.2 amended.

In Section 1909.2 of the California Building Code, delete "Walls and..." from subsection number 3.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.666 - CBC Section 1909.4 amended.

In Section 1909.4 of the California Building Code, delete ."..walls..." from the sentence beginning "Structural plain concrete...," and also delete the Exception in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.668 - CBC Section 1909.6 deleted.

Delete Section 1909.6 of the California Building Code in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.669 - CBC Section 2304.7.1 amended.

In Section 2304.7.1 of the California Building Code, delete 2304.7(1) and 2304.7(2) after "Floor sheathing conforming to the provisions of Table..." in the second paragraph.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.670 - CBC Section 2304.7.2 amended.

In Section 2304.7.2 of the California Building Code, delete 2304.7(1) and 2304.7(2) after "Roof sheathing conforming to the provisions of Table..." in the second paragraph.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.671 - CBC Section 2304.9.5.2 deleted.

Delete Section 2304.9.5.2 of the California Building Code in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.672 - Item 5 added.

After item 4, add item 5: "Anchor bolts are spaced no further than 48" in a direction parallel to the sill plate."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.673 - CBC Section 2306.4 amended.

In Section 2306.4, replace the following ."..Seismic Design Category E or F." with ."..Seismic Design Category D, E, or F."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.674 - CBC Section 2308.3.3 amended.

In Section 2308.3.3 of the California Building Code, at the end of the second sentence, delete the phrase, ."..for structures over two stories above grade plane."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.676 - CBC Section 2308.6 amended.

In Section 2308.6 of the California Building Code:

A.

In the third sentence beginning with "Foundation plates or sills...," replace "½-inch diameter (12.7mm) steel bolts" with "⅝"-inch diameter (15.9mm) steel bolts."

B.

In Section 2308.6, in the fourth sentence beginning with "Bolts shall be...," replace "6 feet (1829mm) apart" with "4 feet (1219mm) apart, and adequately secured in-place by an approved method before placement of concrete or grout."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.677 - CBC Section 2406.3 amended.

In Section 2406.3, item 5 of the California Building Code, add ."..or within 3 feet measured horizontally of such fixtures or compartments..." in the second sentence after the phrase ."..a building wall enclosing these compartments...."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.678 - CBC Section 2509.3 amended.

In Section 2509.3 of the California Building Code, add the following:

A.

a new note as follows: "4. As backing board for glue-on thinset tile."

B.

a new second paragraph as follows:

 The following typical installations for walls in showers and water closets are acceptable pursuant to this section. All of the following finishes shall extend a minimum of seventy inches above the adjacent tub or shower drain. Joint and nail treatment and installation shall be pursuant to specific manufacturer's installation instructions.

1.  Marble Finish

a.  No building paper on stud face.

b.  Water-resistant gypsum backing board with nailing inspection required.

c.  Glued-on marble or marble equivalent

2.  Thinset and Glue-on Tile

a.  Building paper on stud face.

b.  Cementitious backer unit (CBU) installed in accordance with manufacturer's instructions. Instructions on jobsite at time of inspection.

c.  Tile (thinset or glue-on).

d.  Finish grout.

3.  Tile

a.  No building paper on stud face.

b.  Water-resistant gypsum backer board (greenboard).

c.  Paper/lath with inspection required

d.  Scratch coat

e.  Tile installation

f.  Finish grout

4.  Fiberglass kits (does not include solid one-piece units) which have been approved by I.A.P.M.O. (or other approved testing and listing agency) for use in tub/shower walls

a.  No building paper on stud face.

b.  Water-resistant gypsum backer board (greenboard) with inspection required.

c.  Fiberglass kit installation per manufacturer's instructions with instructions available to inspector on the jobsite.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.679 - CBC Section 3201.4 deleted and replaced.

In Section 3201.4 of the California Building Code, replace this section in its entirety with the following:

3201.4 Site drainage.

 Surface, subsurface, potable, and equipment drainage water shall be conveyed in an approved manner to an adequate and approved downstream transportation facility.

 In Section 3202.1 of the California Building Code, replace this section in its entirety with the following:

3202.1 Encroachments below grade.

 Encroachments into the public right-of-way below grade shall conform with the requirements of Oakland Municipal Code Chapter 12.08.

 In Section 3202.2 of the California Building Code, replace this section in its entirety with the following:

3202.2 Encroachments above grade.

 Encroachments into the public right-of-way above grade shall conform with the provisions of Chapter 12.08 of the Oakland Municipal Code and as provided for in Sections 3202.2.1 through 3202.2.3.

3202.2.1 Doors.

 Doors shall not swing over the public right-of-way in any position by more than twelve (12) inches.

3202.2.2 Signs.

 Encroachments of signs over the public right-of-way shall conform with the provisions of the Oakland Sign Code.

3202.2.3 Unenclosed balconies, architectural features, awnings, canopies.

 Unenclosed balconies, architectural features, canopies over entrance doors, and awnings over windows may cantilever over the public right-of-way by not more than one inch horizontally for each one inch of vertical clearance exceeding eight feet, measured from the higher of finished grade or public walking surface to the lowest overhead element of the encroachment. The encroachment shall not project more than four feet. Projecting structural elements shall be fire-resistive construction or noncombustible.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.680 - CBC Section 3305.1 amended.

In Section 3305.1 of the California Building Code, replace ."..the California Plumbing Code" with ."..Section 15.04.070 of this Code."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.681 - CBC Section 3307.1 amended.

In Section 3307.1 of the California Building Code, replace the fourth sentence beginning with "The person making or causing an excavation..." in its entirety with the following:

 "Adjoining property owners shall be provided adequate notice of pending excavation and sufficient time allowance for completing protective measures, and their buildings and structures shall be provided adequate subjacent support in accordance with the provisions of California Civil Code Section 832."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.682 - CBC Section 3401.2 amended.

In Section 3401.2 of the California Building Code, replace this section in its entirety with the following:

 "Buildings, structures, portions thereof, and fire-protection, detection, and alarm systems shall be maintained in accordance with the Oakland Building Maintenance Code and the Oakland Fire Code."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.683 - CBC Section 3401.4.3 amended.

In Section 3401.4.3 of the California Building Code, delete the word "Replacement" in the section title and in the first sentence.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.684 - CBC Section 3403.1.1 amended.

In Section 3403.1.1 of the California Building Code, delete the word "Replacement" in the section title and in the first sentence.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.685 - CBC Section 3404.1 amended.

In Section 3404.1 of the California Building Code, replace this exception 1 in its entirety with the following:

 "Where the partial repair of a stairway, guardrail, or handrail does not exceed 33% of the existing section of repaired elements, and the existing section is in accordance with the code that was current at the time of original construction, and the existing section does not continue or exacerbate an unsafe condition, then the repair may match the existing construction. Repairs to existing stairways with masonry or concrete surfacing exceeding four inches in thickness and supported by wood framing may conform with the provisions of this section.

 If the repair of the wood framing does not exceed 33% of the existing wood frame section being repaired, and the masonry or concrete surfacing is in sound condition with nothing more than shrinkage cracks, and the rise and run of the stairway are in accordance with the code that was current at the time of original construction, and the stairway has positive drainage and has not settled excessively towards or away from the building; and the existing section does not continue or exacerbate an existing condition, the repair may match the existing construction.

 All replacement of the wood framing supporting the masonry or concrete surfacing shall be factory pressure preservative treated. All replacement wood framing within six inches of the ground shall be pressure preservative treated approved for direct ground contact. All end field cuts of pressure preservative treated wood shall be properly treated with preservative."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.686 - CBC Section 3404.1.1 amended.

In Section 3404.1.1 of the California Building Code, delete the word "replacement" in the first sentence.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.687 - CBC Section 3405.1.2 amended.

In Section 3405.1.2 of the California Building Code, delete the word "replacement" in the first sentence.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.688 - CBC Section 3406 amended.

In Section 3406 of the California Building Code, delete Section 3406.1.1, Section 3406.1.3, Section 3406.1.4, Section 3406.2, Section 3406.3, and Section 3406.4 in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.689 - CBC Section 3408.1 amended.

In Section 3408.1 of the California Building Code, delete the sentence beginning "Subject to the approval of the Building Official..." in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.690 - CBC Sections 3408.3 and 3412 deleted.

In Section 3408.3 and Section 3412 of the California Building Code, delete these two sections in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.691 - CBC Section 3408.4 amended.

In Section 3408.4 delete the first sentence and replace with "When a change is made in the use or occupancy of any building that would place the building in a different division of the same group of occupancies or in a different group of occupancies, the structure shall conform to the seismic requirements for a new structure."

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.692 - CBC Section 3411.4.1 deleted and replaced.

In Section 3411.4.1, delete this section in its entirety and replace with, "Where a portion of the building is changed to a new occupancy classification, any alterations shall comply with the requirements of Chapter 11A or 11B as applicable for new construction.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.693 - CBC Section 3411.4.2 deleted and replaced.

In Section 3411.4.2, delete this section in its entirety and replace with, "Where an entire building undergoes a change of occupancy, it shall comply with Chapter 11A or 11B as applicable for new construction.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.694 - CBC Section 3411.5 amended.

In Section 3411.5, delete the second sentence beginning with "An addition that affects..." in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.695 - CBC Sections 3411.6, 3411.7, 3411.8, and 3411.9 deleted.

Delete Sections 3411.6, 3411.7, 3411.8, and 3411.9 in their entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.696 - CBC Appendix I adopted.

Adopt Appendix I - Patio Covers of the California Building Code in its entirety.

(Ord. No. 13047, §§ 2, 3, 11-9-2010)

15.04.697 - Chapter 3B added.

Add the following new Chapter 3B for Joint Living and Work Quarters:

Chapter 3B
USE AND OCCUPANCY

Division 1
Requirements for Joint Living and Work Quarters

Group F — Division 7 and 8

Group R — Division 7, 7.1, and 8

SECTION 3B.1 — General.

Section 3B.1.1 Purpose.

 The purpose of this division is to provide alternative building standards and minimum standards of safety for commercially/industrially-oriented and residentially-oriented Joint Living and Work Quarters (JLWQ) purposes pursuant to California State Health and Safety Code (SCHSC) Section 17958.11. For clarification purposes, portions of Health and Safety Code Section 17958.11 is repeated as follows:

"(a) Any city or county may adopt alternative building regulations for the conversion of commercial or industrial buildings, or portions thereof, to joint living and work quarters. As used in this section, "joint living and work quarters" means residential occupancy by a family maintaining a common household, or by not more than four unrelated persons, of one or more rooms or floors in a building originally designed for industrial or commercial occupancy which include: (1) cooking space and sanitary facilities in conformance with local building standards adopted pursuant to CSHSC Section 17958 or 17958.5 and (2) adequate working space reserved for, and regularly used by, one or more persons residing therein...

 It is the intent of the (California) Legislature that local governments have discretion to define geographic areas which may be utilized for joint living and work quarters and to establish standards for such occupancy, consistent with the needs and conditions peculiar to the local environment. The Legislature recognizes that building code regulations applicable to residential housing may have to be relaxed to provide joint living and work quarters in buildings previously used for commercial or industrial purposes."

Section 3B.1.2 Scope.

 The provisions of this division shall apply to and may be used only for buildings or portions thereof originally designed for commercial or industrial purposes that have received City Planning approval for use as Joint Living and Work Quarters (JLWQ). City Planning approval shall be pursuant to Section 17.102.190 of the Oakland Planning Code or other City Planning approval indicating that the proposed use is consistent with California State Health and Safety Code Section 17958.11.

Section 3B.1.3 Applicability of City Planning and other Criteria for Joint Living and Work Quarters.

 As provided in California Health and Safety Code Section 17958.11 and the Oakland Planning Code, the residential occupancy of joint living and work quarters is an accessory use to its primary use as a place of work. Accordingly, the provisions of this division shall apply only to buildings or portions of buildings that meet the following criteria:

1.  The minimum floor area of an individual JLWQ shall be 660 square feet.

2.  A minimum of 67% of the floor area of an individual JLWQ shall be designated as work area and the remainder shall be designated as residential area pursuant to paragraph 3 below. Up to 25% of the designated work area may be used for dual purposes such as telephoning, drawing, accounting, reading, planning, development of work projects, and sanitary facilities.

3.  The areas of an individual JLWQ used for living, sleeping, eating, and cooking (habitable space) shall be designated as residential area. The residential area shall be secondary to the work area and shall not exceed 33% of the floor area of the individual JLWQ.

4.  In an individual JLWQ, a designated residential area of up to 300 square feet may provide residence for no more than two persons. An additional resident can be accommodated for each additional 150 square feet of designated residential area. No individual JLWQ shall accommodate more than 10 persons regardless of the size of the designated residential area.

EXCEPTION: Residentially-Oriented Live-Work in the Urban Core may be in compliance with Planning Approval pursuant to interim measures adopted by the City Council or other City Planning approval as applicable.

Section 3B.1.4 Applicability of other Provisions.

 Except as specified within this division, JLWQ that are commercially/industrially-oriented shall meet all applicable provisions of this code as for an F-1 Occupancy and JLWQ that are residentially-oriented shall meet all applicable provisions of this code as for an R-2 Occupancy apartment residential dwelling unit.

SECTION 3B.2 — Definitions.

Section B.2.1 Joint Living and Work Quarters (JLWQ).

 Joint Living and Work Quarters are defined in Section 17.102.190(b) of the Oakland Planning Code, which is repeated here for clarification purposes as follows:

"Joint living and work quarters means residential occupancy by not more than four persons, maintaining a common household of one or more rooms or floors in a building originally designed for industrial or commercial occupancy which includes: (1) Cooking space and sanitary facilities which satisfy the provisions of other applicable codes, and (2) Adequate working space reserved for, and regularly used by, one or more persons residing therein."

Section 3B.2.2 Joint Living and Work Quarters shall meet all of the criteria of Section 3B.1.1.

Section 3B.2.3 Commercially/Industrially Oriented JLWQ.

 A single-tenant space combining working and living uses with or without interior walls where the work use is the same as a use that by itself would be classified as a Group F, Division 1 or Division 2 Occupancy or as a Group B Occupancy (excluding drinking and dining establishments and food handling activities with on-site food sales and excluding certain business occupancies similar to animal hospitals, kennels, pounds; automobile and other motor vehicle showrooms; banks; car washes; civic administration; outpatient clinic and medical offices; dry cleaning or laundry pick-up and delivery stations and self-service; fire stations; police stations; and post offices), and where the residential use is the same as one that by itself would be classified as a Group R, Division 2 or 3 Occupancy. A Commercially/Industrially-Oriented JLWQ consists of a Designated Work Area and a Designated Residential Area.

Section 3B.2.4 Residentially Oriented JLWQ.

 A single-tenant space combining working and living uses with or without interior walls where the residential use is the same as a use that by itself would be classified as a Group R, Division 2 Occupancy, and where the work use, by itself, is no more hazardous than that which is normally permitted in residential facilities, and the work use is the same as one that by itself would be classified as a Group B Occupancy (excluding drinking and dining establishments and food handling activities with on-site food sales and excluding certain business occupancies similar to animal hospitals, kennels, pounds; automobile and other motor vehicle showrooms; banks; car washes; civic administration; outpatient clinic and medical offices; dry cleaning or laundry pickup and delivery stations and self-service; educational occupancies above the 12th grade with more than ten occupants; fire stations; police stations; and post offices) and Group F, Division 1 Occupancy. Work uses classified as Group F, Division 2 Occupancies, when the scale and intensity of the activity is limited, may be permitted if a request in approved form and content for alternate materials, alternate design and methods of construction is submitted to and approved by the Building Official. A Residentially-Oriented JLWQ consists of a Designated Residential Area and a Designated Work Area.

Section 3B.2.5 Residentially Oriented Live-Work in the Urban Core.

 A change of use of an existing commercial and non-residential use to a residentially-oriented JLWQ in the Central Business District designation of the Planning Regulations General Plan or other designation as determined by the Planning Division in accordance with the Planning Regulations.

Section 3B.2.6 Designated Residential Area.

 The portion of an individual space that is designed and used for living, sleeping, eating, and cooking by one or more persons who also work in the Designated Work Area of that space. It is considered Habitable Space.

Section 3B.2.7 Designated Work Area.

 The portion of an individual space that is designed and used for work purposes by one or more persons residing in the Designated Residential Area of that space. It is not considered Habitable Space.

Section 3B.2.8 Group F, Division 7 Occupancy.

 Commercially/industrially oriented Joint Living and Work Quarters.

Section 3B.2.9 Group F, Division 8 Occupancy.

 Commercially/industrially oriented Joint Living and Work Quarters that meet current code with allowance for certain specific equivalent alternatives.

Section 3B.2.10 Group R, Division 7 Occupancy.

 Residentially-oriented Joint Living and Work Quarters.

Section 3B.2.11 Group R, Division 7.1 Occupancy.

 Residentially-oriented live-work (Joint Living and Work Quarters) in the Urban Core.

Section 3B.2.12 Group R, Division 8 Occupancy.

 Residentially-oriented Joint Living and Work Quarters that meet current code with allowance for certain specific equivalent alternatives.

Section 3B.2.13 Related Definitions.

 For Floor Area, see Section 202 of the California Building Code.

 For Habitable Space (Room), see Section 202 of the California Building Code.

SECTION 3B.3 — Additional Permit Application Requirements.

Section 3B.3.1 Plans and Specifications.

 In addition to the provisions of the California Building Code and this chapter for information on Plans and Specifications, the plans for JLWQ shall contain and clearly show the following:

1.  The architect or civil engineer of record for the project along with pertinent contact information pursuant to this Code;

2.  Nature of all City Planning approvals required and obtained, including use as JLWQ pursuant to this chapter, and show any City Planning conditions of approval within the plans;

3.  The California Energy Commission Standards (Residential or Non-residential) which are being applied and the areas of the building and the individual JLWQ to which they are being applied and show the required energy documents within the plans;

4.  Note regarding the nature of "notice of limitations" to be filed, or if previously filed show the notices within the plans;

5.  Note on plans regarding the nature of the permit: for (complete) (partial) conversion of an existing building to the specific occupancy with complete build-out of individual spaces, or for (complete) (partial) shell conversion of existing building to the specific occupancy with individual spaces to be completed under separate permit; or for finished improvement of an individual tenant space within a previously converted or constructed shell building or portion of building; [or as applicable for other than JLWQ: for new complete building; or for new shell building];

6.  Any additional information as required or requested by the Fire Marshal or Building Official;

7.  Occupancy—All existing occupancies of the building and the boundaries of the occupancies;

8.  Type of construction — All existing types of construction of the building and the boundaries of the types of construction, indicate the fire-resistance of the building elements. The building elements to be indicated are listed in Table 6-A;

9.  Location on property — Indicate the distance from property line to the existing exterior walls and openings. Indicate any openings that are protected. Indicate the fire-resistance of the existing exterior walls;

10.  Floor area — Indicate existing floor areas including mezzanine areas. Show floor areas of existing occupancies;

11.  Height and number of stories — Indicate existing building height and number of stories and mezzanines within a story;

12.  Occupant load — Indicate existing occupant load and exits or lack of exits for various portions and rooms of the building based on Table 1004.1.1;

13.  Indicate number and location of any existing individual spaces and the extent of their conformance with current code provisions ("notice of limitation" on file?, fire-resistive construction? etc. also see Numbers 25 through 33 below) and percentage of the story and building floor area they occupy;

14.  Indicate extent and nature of any existing fire-protection systems within the building;

15.  Nature, location, and extent of any existing hazardous material control areas;

16.  Occupancy — Show all proposed occupancies of the building and for existing buildings the portions which are changing occupancy and the boundaries of the proposed occupancies;

17.  Type of construction — Show all the types of construction proposed for the building and the boundaries of the type of construction. If some elements of an existing building are upgraded to achieve a certain type of construction indicate the nature of the upgrade to achieve the proposed type of construction;

18.  Location on property — Indicate fire-resistive requirements based on location of property and for existing buildings those openings or walls that are being upgraded to meet current code provisions for existing and proposed occupancies;

19.  Floor area — Indicate floor areas including mezzanine areas of proposed occupancies and calculate allowable floor areas for existing and proposed occupancies to meet current code provisions;

20.  Height and number of stories — Indicate proposed building height and number of stories and the allowable height and number of stories for existing and proposed occupancies to meet current code provisions;

21.  Occupant load — Indicate occupant load of the proposed and existing occupancies to remain based on current code provisions;

22.  Indicate number and location of any proposed individual JLWQ spaces and percentage of the building floor area they occupy and also, if there are existing JLWQ in the building, the combined percentage of the story floor area and the building floor area that the proposed and existing JLWQ occupy;

23.  Indicate extent and nature of any proposed, or changes to existing, fire-protection systems within the building;

24.  Indicate nature, location, extent, and details of any proposed and existing hazardous material control areas;

25.  Nature of "notice of limitations" that affect the specific spaces(s);

26.  Nature of application of disabled regulations that affect the specific individual space(s);

27.  Nature of California Energy Commission Standards that affect the specific individual space(s) or for JLWQ if the prescriptive insulation and heating provisions are being used;

28.  Total floor area of each individual space and location and floor area of its designated work area and its designated residential area and their respective percentages of the individual unit total floor area;

29.  The maximum number of persons that may be accommodated (reside in) within each individual space;

30.  The floor and mezzanine areas and number of floors and mezzanines (including sleeping mezzanines) within each individual space;

31.  Whether Section 3B.8.2.3.1, 3B.8.2.3.2, or 3B.8.2.3.3 for increased mezzanine (including sleeping mezzanine) percentage of superficial floor area is being applied;

32.  Location of the sleeping area(s) of each individual space; and

33.  Amount of hazardous materials to be involved or allowed pursuant to Section 3B.16.1 and location and details for any hazardous control area(s) necessary within the individual space.

Section 3B.3.2 Notice of Limitation Regarding an Individual F-7 or 8 or R-7, 7.1, or 8 Occupancy Space Having Employees and/or Being Regularly Open to the Public.

 When an individual F-7 or 8 or R-7, 7.1 or 8 Occupancy space is proposed in a building or a portion of a building the following shall be provided:

1.  A "notice of limitation" for the building is recorded with the Alameda County Recorder's Office indicating whether or not employees are permitted and/or if the individual space is regularly open to the public; and

2.  If appropriate, the Conditions, Covenants, and Restrictions administered by a owner's association shall delineate the conditions by which employees and/or being regularly open to the public are or are not permitted OR if appropriate, the standard lease shall delineate the conditions by which employees of the tenant of the individual space are or are not permitted and/or whether or not the individual space is regularly open to the public. A copy of either shall be attached as Exhibit "A" to the "notice of limitation."

 Reference to this notice and whether employees and/or being regularly open to the public or not shall be indicated on the permit application.

 Recording such a notice of limitation stating that employees are allowed and that an individual space is regularly open to the public shall not permit employees or being regularly open to the public if this is contrary to City Planning or other superseding conditions or regulations.

Section 3B.3.3 Notice of Limitation for Use of Ship Stair or Ladder within an Individual F-7 or R-7 or R-7.1 Occupancy JLWQ.

 A "notice of limitation" shall be recorded with the Alameda County Recorder's Office with a waiver of damages and holding the City harmless for any litigation relating to access provisions in an individual JLWQ provided pursuant to Sections 3B.12.4.3, 3B.12.4.4, and 3B.12.4.5.

Section 3B.3.4 Notice of Limitation for Use of Alternative Emergency Escape and Rescue for Existing Buildings.

 A "notice of limitation" shall be recorded with the Alameda County Recorder's Office with a waiver of damages and holding the City harmless for any litigation relating to alternative emergency escape and rescue provisions when such alternatives are used and provided for in an existing building pursuant to Section 3B.12.6.3.1.

Section 3B.3.5 Notice of Limitation Regarding an Individual F7 or 8 Occupancy Space Being a Noise Source Greater than 60db.

 When F-7 or 8 Occupancy individual spaces are proposed in a building or a portion of a building the following shall be provided:

1.  A "notice of limitation" for the building is recorded with the Alameda County Recorder's Office indicating the limitations and requirements for mitigation of excessive noise generation; and

2.  As appropriate, the Conditions, Covenants, and Restrictions administered by a owner's association or the Standard Lease Agreement for the space shall state that when an individual JLWQ has a regular use on a continuing basis that has a noise source above 60db the individual tenant and/or owner will comply with the provisions of Section 3B.18.3.2 relating to additional airborne sound and impact insulation for the space.

SECTION 3B.4 — Change of Occupancy.

Section 3B.4.1 General.

 Changing the occupancy of an existing building to a commercially/industrially-oriented JLWQ, Group F, Division 7 or 8 Occupancy, or to a residentially-oriented Group R, Division 7, 7.1 or 8 Occupancy shall be considered a change of occupancy and such buildings shall comply with the applicable requirements of the California Building Code and this chapter including the fire, life safety, structural, and seismic requirements.

EXCEPTIONS:

1.  For Group F-7 or R-7 Occupancies in existing buildings minimum seismic requirements may be met if the building substantially conforms, or is altered to conform, to 75% of the California Building Code seismic and wind load design standards. Unreinforced masonry (URM) bearing wall buildings, in lieu of the above design standards, may comply with the current California Existing Building Code, Title 24, Part 10, Appendix Chapter 1. Concrete tilt-up and non-ductile concrete framed buildings that conform to the above standards will still be subject to any future seismic upgrade regulations for these types of buildings unless these buildings conform, or are altered to conform, to current code requirements.

2.  For Group R-7.1 Occupancies in existing buildings minimum structural requirements may be met if the building substantially conforms, or is altered to conform to Sections 3B.4.2 and 3B.5. Unreinforced masonry (URM) bearing wall buildings, in-lieu of the above design standards, may comply with the current California Existing Building Code, Title 24, Part 10, Appendix Chapter 1. Concrete tilt-up and non-ductile concrete framed buildings that conform to the above standards will still be subject to any future seismic upgrade regulations for these types of buildings unless these buildings conform, or are altered to conform, to current code requirements.

3.  The occupancy of a story of an existing building or portion of the building may be changed to a Group F, Division 7 Occupancy or a Group R, Division 7 Occupancy or a Group R, Division 7.1 Occupancy without requiring that the entire building comply with all the requirements of this code if all of the following conditions are present or provided:

3.1  No more than 10% of the floor area of the entire building or of an individual story is or will become designated residential area and no more than ten residents are accommodated on an individual story of the building pursuant to Section 3B.1.3;

3.2  The existing building, its use, its appendages, and/or its structural system is not declared an unsafe building or structure pursuant to this code or considered unsafe pursuant to other regulations;

3.3  The entire building is made to conform with all the minimum standards for existing buildings in Chapter 34 of the current California Building Code;

3.4  Other than for work required to comply with the current California Existing Building Code, Title 24, Part 10, Appendix Chapter 1 or Chapter 34 of the current California Building Code pursuant to 3.3 above, additions, alterations, and repairs shall comply with current code; and

3.5  The designated work area and the designated residential area of each individual JLWQ comply with the requirements of this chapter.

Section 3B.4.2 Structural Survey For R-7.1 Occupancy.

Section 3B.4.2.1.

 Every structure or portion of a structure to be evaluated for structural capacity under this code shall be surveyed for structural conditions by an architect or engineer knowledgeable in historical structures. The survey shall document deterioration or signs of structural distress. The survey shall determine the details of the structural framing and the system for resistance of gravity and lateral loads. Details, reinforcement and anchorage of structural systems and veneers shall be determined and documented.

Section 3B.4.2.2.

 The results of the survey shall be utilized for designing modifications to the structural system to reach compliance with this code.

SECTION 3B.5 — Structural Regulations for R-7.1 Occupancy.

Section 3B.5.1 Gravity Loads.

 The capacity of the structure to resist gravity loads shall be evaluated and the structure strengthened as necessary. The evaluation shall include all parts of the load path, if the evaluation indicates that no structural distress is evident, and a complete load path is present, the structure may be assumed adequate for gravity loads by having withstood the test of time if anticipated dead and live loads will not exceed those historically present.

Section 3B.5.2 Wind and Seismic Loads.

 The ability of the structure to resist wind and seismic load shall be evaluated. The evaluation shall be based on the requirements of California Historical Building Code, Title 24, Part 8. Any unsafe conditions in the lateral-load-resisting system shall be corrected, or alternative resistance shall be provided. Additional resistance shall be provided to meet the minimum requirements of this code. The architect or engineer shall consider additional measures with minimal loss of, and impact to, historic materials which will reduce damage and needed repairs in future earthquakes to better preserve the historical structure in perpetuity. These additional measures shall be presented to the owner for consideration as part of the rehabilitation or restoration.

Section 3B.5.3 Lateral Load Regulations for R-7.1 Occupancy.

Section 3B.5.3.1 Lateral Loads.

 The forces used to evaluate the structure for resistance to wind and seismic loads need not exceed 0.75 times the seismic forces prescribed by the current edition of the California Building Code (CBC). The seismic forces may be computed based on the R values tabulated in the CBC for similar lateral force-resisting systems. All deviations of the detailing provisions of the lateral-force-resisting systems shall be evaluated for stability and the ability to maintain load-carrying capacity at increased lateral loads. Unreinforced masonry bearing wall buildings shall comply with California Existing Building Code, Title 24, Part 10, Appendix Chapter 1, and as modified by this code. Reasonably equivalent standards may be used on a case-by-case basis when approved by the authority having jurisdiction.

Section 3B.5.3.2 Existing Building Performance.

 The seismic resistance may be based upon the ultimate capacity of the structure to perform, giving due consideration to ductility and reserve strength of the lateral-force-resisting system and materials while maintaining a reasonable factor of safety. Professional engineering judgment may be exercised regarding the strength and performance of materials not recognized by regular code requirements. (California Historical Building Code, Title 24, Part 8)

Section 3B.5.3.3.

 All structural materials or members that do not comply with detailing and proportioning requirements of the regular code shall be evaluated for potential seismic performance and the consequence of noncompliance. All members which might fail and lead to possible collapse, or threaten life safety, shall be judged unacceptable and appropriate structural strengthening shall be developed. The building should be evaluated as a system to ensure against progressive collapse.

Section 3B.5.3.4 Load Path.

 A complete and continuous load path, including connections, from every part or portion of the structure to the ground shall be provided for the required forces. It shall be verified that the structure is adequately tied together to perform as a coherent system when subjected to earthquake forces.

Section 3B.5.3.5 Parapets.

 Parapets and exterior decoration shall be investigated for conformance to the regular code requirements for anchorage and ability to resist prescribed seismic forces. An exception to regular code requirements shall be permitted for those parapets and decorations which are judged not to be a hazard to life safety.

Section 3B.5.3.6 Historical Records.

 Historical records of the structure or similar structures may be used in the evaluation, including the effects of subsequent alterations.

Section 3B.5.3.7 Nonstructural Features.

 Nonstructural features of a structure converted to R-7.1 use, such as exterior veneer, cornices and decorations, which might fail and create a life-safety hazard in an earthquake, shall be investigated. Their ability to resist seismic forces shall be verified, or the feature shall be strengthened.

Section 3B.5.3.8.

 Partitions and ceilings of corridors and stairways serving an occupant load of 30 or more or located above the first story shall be investigated to determine their ability to remain in place when the building is subjected to earthquake forces.

SECTION 3B.6 — Minimum Facilities and Shell Construction.

Section 3B.6.1 General.

 All individual spaces and JLWQ shall be provided with facilities pursuant to applicable code with not less than the minimum facilities as provided herein. See Table 3B.6-A.

Section 3B.6.2 Minimum Shell Facilities.

 Where a building shell is proposed to be constructed or an existing building shell conversion with improvements and facilities within an individual space or JLWQ to be constructed later under separate permits, roughed-in facilities shall be provided pursuant to applicable code sufficient to serve the proposed facilities with not less than the minimum facilities pursuant to Table 3B.6-A. The shell shall be constructed pursuant to applicable code with minimum facilities as provided herein.

Section 3B.6.3 Finished Facilities.

 Where the individual space is to be completely finished, facilities shall be provided pursuant to applicable code with not less than the minimum facilities pursuant to Table 3B.6-A. All fixtures, equipment and appurtenances plus all plumbing, mechanical, and electrical requirements shall be installed for a complete and finished space.

Section 3B.6.4 Combustion Air Through Infiltration.

 If the individual space cannot provide sufficient combustion air or ventilation through infiltration as defined in and pursuant to the California Plumbing Code and/or California Mechanical Code, as applicable, then the minimum facilities in a room, individual space, or building of unusually tight construction shall provide roughed-in or completed facilities for combustion air and ventilation.

Section 3B.6.5 Shell Construction.

 The building shell construction shall meet all requirements of this code and this division. The building shell itself, public use areas, common use areas, and walls and floor/ceilings separating and common to the individual space or JLWQ shall be completely constructed as part of the building permit work for the shell. All plumbing work, mechanical work, and electrical work, including the provisions for minimum facilities pursuant to Table 3B.6-A, serving an individual space of F-7 or R-7 OR R-7.1 Occupancy JLWQ or F-8 or R-8 Occupancy shall be appropriately enclosed, terminated and labeled.

Section 3B.6.6 Individual Space or JLWQ.

 The individual space or JLWQ that will be improved at a later time will be required to obtain a separate permit and shall comply with all permit and inspection requirements of the applicable code in effect at the time of permit application.

TABLE 3B.6-A

Individual spaces shall be provided with or for shell construction have the capability of installing kitchen, bathroom water heater, and space heating facilities in the space without performing work within other units or within common walls or floor/ceiling separating individual spaces. The minimum roughed-in facilities (with minimum facilities if finished) to be provided are:
A)  Kitchen Facilities (finish facilities shall include kitchen sink, range, and vent hood if required plus all electrical and plumbing):
 1) Two 20 amp electrical circuits for small appliances;
 2) One 20 amp circuit for the refrigerator;
 3) A two inch waste line for a sink;
 4) Hot and cold water supply and shut-off valves;
 5) One 60 amp circuit or a gas line sufficient for a domestic range;
 6)  If a gas range is proposed in a building of unusually tight construction as defined in the CMC, provisions for combustion air and venting shall be provided in accordance with the CMC; and
 7) Provisions for a range hood vent for a gas range shall be provided.
B)  Bathroom Facilities (finished facilities include installation of all fixtures):
 1) A one and a half inch waste line for a lavatory;
 2)  A two inch waste line for a shower or a one and half inch waste line for a bathtub (provide access if a slip joint is used at the proposed tub);
 3) A three inch waster line for a water closet;
 4)  Hot and cold water supply for a lavatory, shower or bathtub, and water closet and shut-off valves for the lavatory and water closet; and
 5) Provisions for ventilation pursuant to CMC and CBC Section 1203.4.2.1.
C) Water Heater (finish facility includes installed water heater and all appurtenances):
If the building shell does not provide a hot water supply to the individual JLWQ, facilities to allow installation of a water heater within the individual JLWQ shall be provided as follows:
 1)  A gas line sufficient to supply the water heater; and/or when permitted pursuant to the CEC Energy Conservation Regulations adequate electrical capacity for the electric water heating equipment;
 2)  A minimum ¾ inch drain line for a water heater drain pan to an approved location (such as outside the building, to a floor drain, utility sink, etc.) when a water heater is located in an attic or furred space pursuant to the CPC;
 3)  A drain line for a water heater relief line pursuant to the CPC to the outside of the building or to another approved location (with prior approval by the Building Official);
 4)  Provision for water heater vent pursuant to the CPC;
 5)  If the building is of an unusually tight construction, provision shall be provided for combustion air for the water heater other than infiltration pursuant to the CPC.
D)  Space Heating (finish facilities include complete space heating installation and all appurtenances):
In areas of the JLWQ where heat is required or proposed, the following shall be provided:
 1)  A gas line sufficient for supply to the space heating equipment; and/or when permitted pursuant to the CEC Energy Conservation Regulations adequate electrical capacity for the space heating equipment;
 2)  Provisions for appropriate venting and combustion air supply for the space heating equipment; and
 3)  Adequate appurtenant electrical facilities including thermostatic wiring.

SECTION 3B.7 — Construction, Height, and Allowable Area.

Section 3B.7.1 General.

 Group F-7 or 8 Occupancy JLWQ shall conform to code requirements for F-1 Occupancies and Group R-7 or 8 Occupancies shall conform to code requirements for R-2 Occupancies as to construction, height and allowable area pursuant to Chapter 3, Chapter 5, Chapter 6, and to related code requirements and to the specific requirements herein.

EXCEPTION: For Group F-7 or R-7 or R-7.1 Occupancies the following alternatives may be used:

1.  Where one-hour fire-resistive construction is required, floors in existing buildings constructed with valid permits may be accepted which have the separation limited to the installation of materials approved for the underside of a one-hour fire-resistive floor/ceiling assembly when the existing flooring system is air-tight and equivalent to a minimum nominal ¾" thick wood floor.

2.  Where one-hour fire-resistive construction is required, walls or ceiling surfaces in existing buildings constructed with valid permits, with wood, lath and plaster in good condition or one-half inch thick gypsum wall board may be accepted when approved by the Building Official.

3.  In an existing building, an approved automatic sprinkler system, as specified in California Building Code, Section 903, may be substituted for one-hour fire-resistive construction, provided such system is not otherwise required throughout the building, including a requirement for sprinklers due to inadequate pressure and flow in the fire hydrants or fire supply that would provide protection to the building.

Section 3B.7.2 Unlimited Area.

 Section 507 of the California Building Code is not applicable to commercially/industrially-oriented F-7 or 8 Occupancy JLWQ in existing buildings, except CBC Section 507 may be applied if a request in approved form and content for alternate materials, alternate design and methods of construction is submitted to and approved by the Building Official (approval is not guaranteed).

Section 3B7.3 Mixed Occupancies.

 Group F-7 or 8 Occupancies shall be separated from other occupancies as for an F-1 Occupancy and Group R-7 or 8 Occupancies as for an R-2 Occupancy with a minimum one-hour fire-resistive occupancy separation to all other occupancies.

Section 3B.7.4 Special Provision.

 Walls and floors separating individual Group F-7 or 8 and Group R-7 or 7. 1 or 8 Occupancy JLWQ from other individual JLWQ spaces shall be not less than one-hour fire-resistive construction. Storage or laundry rooms that are used in common by occupants of F-7 or 8 and R-7 or 7.1 or 8 Occupancies shall be separated from the rest of the building by not less than one-hour fire-resistive occupancy separation.

SECTION 3B.8 — Specific Use Provisions.

Section 3B.8.1 Room and Space Dimensions.

Section 3B.8.1.1 General.

 Room dimensions and floor areas of Designated Residential Area in an individual JLWQ used for living, sleeping, eating, and cooking (habitable space) shall meet, as a minimum, the requirements of Section 1208 of the California building Code and the provisions for Efficiency Dwelling Units pursuant to Section 1208.4 and requirements herein. Dimensions of areas other than the designated residential area within an individual F-7 or 8 Occupancy space shall be as for an F-1 Occupancy. Also, comply with Section 3B.1.3.

Section 3B.8.1.2 Sleeping Mezzanine Space Dimensions.

 A sleeping mezzanine, which is permitted only in an individual F-7 or R-7 Occupancy JLWQ, shall have space dimensions as provided herein.

Section 3B.8.1.3 Headroom.

 The minimum sleeping mezzanine headroom shall be a headroom "envelope" clearance to the ceiling or any projections from the ceiling that has a height of 4' with an increasing height of 4" vertical to 12" horizontal or steeper running towards the access to the loft. A horizontal ceiling shall be a minimum of 5' 8" above the sleeping mezzanine floor. See Figures A-3B-1A and 1B.

Section 3B.8.1.5 Floor Area.

 The area dimensions of a sleeping mezzanine may be 5' minimum deep by 7' minimum long or 7' minimum deep by 5' minimum long with a maximum area of 120 square feet. At least fifty percent (50%) of the sleeping loft area perimeter shall be open to the common atmosphere of the space in which it is located unless mechanical ventilation or openable window pursuant to CBC Section 1203.4 is provided. The floor area of a sleeping mezzanine shall not exceed the allowable floor area for mezzanines pursuant to Section 3B.8.2.3. See Figures A-3B-1A and 1B.

Section 3B.8.1.6 Built-in Sleeping Bunk Space Dimensions.

 A built-in sleeping bunk, which is permitted only in an individual F-7 or R-7 JLWQ, shall have space dimensions as provided herein.

Section 3B.8.1.7 Headroom.

 The minimum built-in sleeping bunk headroom clearance shall be a headroom "envelope" clearance to the ceiling or any projections from the ceiling with a height of 3' and with an increasing height of 4" vertical to 12" horizontal or steeper running towards the access to the built-in sleeping bunk. The minimum clearance for a flat ceiling shall be 42 inches above the built-in sleeping bunk floor. See Figures A-3B-2A and 2B.

Section 3B.8.1.8 Floor Area.

 A built-in sleeping bunk shall meet the area dimensions requirements for a sleeping mezzanine pursuant to Section 3B.8.2.3. However, the area of the built-in sleeping bunk may not exceed 60 square feet. See Figures A-3B-2A and 2B.

Section 3B.8.2 Mezzanines in Individual JLWQ.

Section 3B.8.2.1 General.

 Mezzanines shall conform to other requirements of this code or as herein provided.

Section 3B.8.2.2 Mezzanine Ceiling Height.

 The ceiling height of a sloping ceiling above a mezzanine may be measured in accordance with CBC Section 1208.2.

Section 3B.8.2.3 Mezzanine Area in Individual JLWQ.

Section 3B.8.2.3.1.

 The area of a mezzanine within an F-7 or R-7 Occupancy JLWQ may be one third of the gross area of the individual JLWQ if the building is fire-sprinklered throughout.

Section 3B.8.2.3.2.

 The area of a mezzanine within an individual F-7 or R-7 Occupancy JLWQ may be one half of the gross area of the individual JLWQ if the building is fire-sprinklered throughout and fire-sprinklers are not otherwise required, including the requirement for fire-sprinklers due to inadequate fire flow in the water supply serving the building. The total area of the mezzanines within and outside the individual JLWQ on any floor or story of the building shall not exceed one-third of the area of the floor or story.

Section 3B.8.2.3.3.

 If the area and type of construction of an existing building and/or the use of area separation walls pursuant to CBC Section 706will not permit additional number of stories for the building the area of the mezzanine of an individual F-7 or R-7 may be one half of the gross area of the individual JLWQ without being classified as an additional story when the building is fire-sprinklered throughout and all of the following conditions exist:

1.  The individual JLWQ has a layer of ⅝" Type "X" gypsum board applied to the existing ceiling and wall on the unit's side of a common ceiling or wall with another unit and also with any corridor;

2.  The buildings interior exit path (corridor, etc.) serving the individual JLWQ has been constructed as for an extent of stairway enclosure appropriate to the configuration of the building, including requirements for smoke-proof enclosure as applicable, pursuant to CBC Section 1022. When a stairway enclosure is not required, the interior exit path shall be constructed as for an exit passageway pursuant to CBC Section 1022. Unless otherwise required, other individual JLWQ's in the building not using the requirements of this section need not be provided with fire-resistive protection on their side of the corridor or exit passageway.

3.  Glazed openings are allowed between the unit and the building's interior exit path (corridor, etc.) if they are double glazed wire glass in steel frames of no more than 15 square feet per unit fronting on the exit path outside of the JLWQ (corridor, etc.). See Figure A-3B-4.

Section 3B.8.3 Yards and Courts.

 Yards and courts with required windows for natural light and ventilation shall be provided pursuant to CBC Section 1206.

Section 3B.8.4 Eaves.

 Eaves over required windows for natural light and ventilation shall be pursuant to CBC Section 705.2.

Section 3B.8.5 Smoke Detectors.

 Smoke detectors shall be provided in individual spaces that shall conform as applicable for new construction and R occupancy to CBC Sections 907.2.11.

Section 3B.8.6 Heating.

Section 3B.8.6.1 General.

 The designated residential area of an F-7 or R-7 JLWQ and the habitable area of an F-8 or R-8 Occupancy shall conform to the requirements of CBC Section 1204. Space heating equipment shall be configured or located so the heated air will be directly circulated to the designated residential portion of the individual JLWQ.

SECTION 3B.9 — Uniform and Concentrated Loads.

 Uniform and concentrated loads shall be pursuant to CBC Table 1607.1 and to new categories added as follows:

TABLE 3B.9-A

Category Description Uniform Load Concentrated Load
21. R-7 JLWQ, R-8 Occupancy Floors at grade or immediately above and below grade and other floors accessible by ramp or elevator. 60 2,000
Floors other than described above including mezzanines. 50 0
Mezzanines, if posting of allowable live load is provided. 40 0
22. F-7 JLWQ, R-8 Occupancy Floors at grade or immediately above and below grade and other floors accessible by ramp or elevator. 75 2,000
Floors other than described above including mezzanines. 60 0
Mezzanines, if posting of allowable live load is provided. 40 0
23. F-7 JLWQ R-7 JLWQ Occupancy Sleeping Mezzanine. 40 0
24. F-7 JLWQ R-7 JLWQ Occupancy; F-8 or R-8 Occupancy in existing buildings Roof Exit Path for Alternative Emergency Escape and Rescue (3 feet minimum wide) 60 0
Roof Exit Queuing Area (area = 3 SF per occupant served at the designated escape point off of the roof). 60 0

SECTION 3B.10 — Conventional Framing Provisions.

Section 3B.10.1 General.

 CBC Section 2308 Conventional Light-Frame Construction Provisions of the California Building Code shall apply to F-7 or R-7 JLWQ Occupancy as for a Group R Occupancy.

Section 3B.10.2 Fire Blocks and Draft Stops.

Section 3B.10.2.1 General.

 Section 708 — Fire Blocks and Draft Stops of the California Building Code applies to F-7 or 8 and R-7 or 8 Occupancies and as herein provided.

Section 3B.10.2.2 Floor Ceiling Assembly.

 Draft stops in floor-ceiling assemblies pursuant to CBC Section 717.3 as for two or more dwelling units and hotels applies to F-7 or 8 and R-7 or 8 Occupancies.

Section 3B.10.2.3 Attics.

 Draft stops in attics pursuant to Section 717.4 as for two or more dwelling units and hotels applies to F-7 or 8 and R-7 or 8 Occupancies.

SECTION 3B.11 — Location on Property.

Section 3B.11.1 General.

 For an F-7 JLWQ, the fire resistance of the exterior walls and openings may comply with the provisions for an R-2 Occupancy when the entire use of an existing building or a portion of an existing building which is being converted to F-7 JLWQ has been for commercial or industrial purposes (See CBC Section 602). Provided that the requirements for an R-2 Occupancy does not create a more hazardous condition to fire and life safety than the existing condition of the walls and openings. Otherwise, requirements for an F-1 Occupancy shall apply to commercially/industrially-oriented F-7 JLWQ Occupancy.

EXCEPTION: When a building complies with the allowable area requirements as for an R-2 occupancy and the F-7 Occupancy is fire-sprinklered, the fire resistance of the exterior walls and openings may comply with the provisions for an R-2 Occupancy.

SECTION 3B.12 — Access and Means of Egress Facilities and Emergency Escapes.

Section 3B.12.1 General.

 Access and means of egress facilities and emergency escapes shall be in conformance with CBC Chapter, Sections 1014 and 1029 and as provided herein.

Section 3B.12.2 Accessibility.

Section 3B.12.2.1 General.

 Spaces Open to the General Public Or Common Use Spaces. Provisions of this chapter notwithstanding, buildings with JLWQ occupancies that have spaces regularly open to the public or for common use of the occupants of the building shall comply with the applicable accessibility regulations pursuant to Chapter 11B.

Section 3B.12.2.2 JLWQ Occupancies without Employees and/or Not Regularly Open to the Public and Not Publicly-funded.

 Buildings or portions of buildings with JLWQ occupancies that are not publicly funded, do not have employees nor are regularly open to the public, nor are commercial spaces may comply either with the residential accessibility requirements of Chapter 11A or with the non-residential accessibility requirements of Chapter 11B of the California Building Code.

Section 3B.12.2.3 JLWQ Occupancies with Employees and/or Regularly Open to the Public and Not Publicly-funded.

 Buildings or portions of buildings with JLWQ occupancies that are not publicly funded, but do have employees and/or are regularly open to the public shall comply with the non-residential accessibility requirements of Chapter 11B of the California Building Code.

Section 3B.12.2.4 Publicly-funded JLWQ without Employees and Not Regularly Open to the Public.

 Buildings with F-7 Occupancy JLWQ that are publicly funded (owned, operated, or maintained by a public jurisdiction) and do not have employees and are not regularly open to the public shall comply with the applicable accessibility regulations for publicly funded residential occupancy pursuant to Chapter 11B and also Federal requirements if more stringent.

Section 3B.12.2.5 Publicly-funded JLWQ with Employees and/or are Regularly Open to the Public.

 Buildings with F-7 Occupancy JLWQ that are publicly funded (owned, operated, or maintained by a public jurisdiction) and do have employees and/or are regularly open to the public shall comply with the applicable accessibility regulations pursuant to Chapter 11B and also Federal requirements if more stringent.

Section 3B.12.3 Means of Egress Facilities.

Section 3B.12.3.1 Number of Exits.

 Number of Exits shall be in conformance with CBC Chapter 10. Occupant Load Factor shall be pursuant to Section 3453.6.

Section 3B.12.3.2 Individual Units of Group F-7 or 8 and R-7 or 8 Occupancies.

 In individual spaces of Group F-7 or 8 or R-7 or 8 Occupancies a minimum of two exits shall be required from the individual space when the number of occupants is 10 or more. For special provision for exits due to hazardous materials in an individual space see Section 348B.1.2.

Section 3B.12.3.3 Existing Building Exits.

 One of the required exits for an existing Building serving an F-7 or R-7 Occupancy may be a fire escape in conformance with Section 8-502 of the California Historical Building Code.

Section 3B.12.4 Stairways.

Section 3B.12.4.1 General.

 Stairways within an individual JLWQ occupancy unit shall comply as a minimum with the requirements for a residential or other private stair where the occupant load is less than ten (10) and as herein provided. Stairways serving two or more individual JLWQ Occupancy units or an occupant load of 10 or more shall comply with CBC Chapter 10, Section 1009 and as herein provided.

Section 3B.12.4.2 Stairways in an Individual F-7 or R-7 JLWQ Occupancy Unit.

 Stairways in an individual unit of F-7 or R-7 or R-9 Occupancy may alternatively comply with Section 3B.12.4.3 for a ship stair access, Section 3B.12.4.4 for a ladder access, or with Section 3B.12.4.5 for other means of access to a mezzanine, sleeping mezzanine, or built-in sleeping bunk. See Figures A-3B-1A & 1B; A-3B-2A and 2B; and A-3B-3.

Section 3B.12.4.3 Ship Stair.

 A ship stair (ship's ladder) which is a fixed ladder within the pitch range of 41.5 to 75 degrees from the horizontal, equipped with treads and stair rails may provide access to a private mezzanine, sleeping mezzanine, or built-in sleeping bunk within an individual unit of F-7 or R7 Occupancy provided a warning sign and illumination are installed at the ship stair to meet the requirements of the Building Official. There shall be 6'8" minimum headroom provided at the top of the ship stair except the headroom clearance for access to a built-in steeping bunk may be 3'6" minimum.

Section 3B.12.4.4 Ladder.

 A ladder may provide access to a sleeping mezzanine or a built-in sleeping bunk within an individual F-7 or R-7 Occupancy if the rungs are 14 inches maximum on center, 20 inches minimum wide, with 7 inches minimum toe space (measured horizontally from the outside of the rung to the face of a wall or other surface) and a safety cage of 30 inches minimum clear dimension is provided above 6'8" height above the bottom of the ladder when the floor to floor height traversed by the ladder is greater than 9 feet and provided that a warning sign and illumination are installed at the ladder to meet the requirements of the Building Official.

Section 3B.12.4.5 Other Means of Individual Unit Stairway Access.

 Other means of access to a sleeping mezzanine or built-in bunk bed by means of prefabricated access equipment (folding stairs, etc.) may be used if equivalent to the above, subject to Building Official approval and provided a warning sign and illumination are installed at the access. Alternative stairways pursuant to CBC Sections 1009.4.3, 1009.8. 1009.9, and 1009.10 may be utilized in F-7 or 8 and R-7 or 8 Occupancies.

Section 3B.12.4.6 Landing at a Sleeping Mezzanine.

 A stairway, ship stair (ship's ladder), ladder or similar equipment providing access to a sleeping mezzanine in a JLWQ shall terminate in a landing with a 3' minimum dimension in any direction The landing shall have 6'8" minimum headroom. There may be a single step up to the floor of the sleeping mezzanine of 12" maximum rise or otherwise steps complying with individual unit residential requirements shall be provided the same width of the landing in the direction up to the floor of the sleeping loft. See Figures A-3B-1A and 1B.

Section 3B.12.4.7 Notice of Limitation.

 See Section 3B.3.3 for a "notice of limitation" required for any access based on Sections 3B.12.4.3, 3B.12.4.4, and 3B.12.4.5.

Section 3B.12.4.8 Existing Stairways Serving Two or More Individual Units or Ten or More Occupants of an F-7 or R-7 Occupancy.

 Existing stairways serving two or more individual units of F-7 or R-7 Occupancies may alternatively comply as provided herein. Fire escapes shall comply with Section 3B.12.3.3.

Section 3B.12.4.9 Existing Width.

 Width of existing stairways shall not be less than 30" clear from wall to wall. Projections into this minimum width shall conform to current code.

Section 3B.12.4.10 Rise and Run.

 Rise and run of existing stairways may conform to the code applicable at the time the existing stairway was constructed provided that the maximum rise does not exceed eight inches and the minimum tread is not less than nine inches.

Section 3B.12.4.11 Headroom.

 Headroom of existing stairways shall not be less than 6 feet 6 inches.

Section 3B.12.4.12 Landings.

 Existing landings of existing stairways may conform to the code applicable at the time the existing stairway was constructed but shall not be less than 30 inches in the direction of travel.

Section 3B.12.4.13 Handrails.

 Existing handrails may conform to the code applicable at the time the existing stairway was constructed. Handrails on both sides of an existing stairway are not required if the existing stairway was originally constructed with a handrail only on one side and the stairway is less than 36 inches in width. The top of existing handrails shall not be less than 32 inches in height above landings and the nosing of treads.

Section 3B.12.4.14 Guards.

 Guards shall conform to CBC Section 1013 but need not exceed 36 inches on existing stairways.

Section 3B.12.4.15 Interior Stairway Construction.

 Existing interior stairway construction may remain if the stairway construction is structurally adequate and the stairway is fully fire-sprinklered.

Section 3B.12.5 The Exit Access.

Section 3B.12.5.1 General

 The exit access shall be pursuant to Section 1014 of the California Building Code and as herein provided.

Section 3B.12.5.2 Separation of Exits.

 When two exits are required in a building that has only one existing exit stairway, a second exit that complies with current code may be constructed next to the existing stairway if the arrangement of the stairways meet the following conditions:

1.  The entry to the stairways are at opposite ends.

2.  Any hallway or corridor connecting the entries to the stairways is constructed pursuant to Section 1004.3.4.3 of the California Building Code.

3.  A horizontal exit wall bisects the building and stairways.

4.  All areas of the floor have access to either stairway.

Section 3B.12.6 Emergency Escape and Rescue.

Section 3B.12.6.1 General.

 Every joint living and work quarters (JLWQ) shall have at least one emergency escape and rescue window or door for each separate sleeping room or sleeping area pursuant to CBC Section 1029 and as provided herein.

Section 3B.12.6.2 Sleeping Area.

 If a sleeping area is located in the common atmosphere of a room, even if the room is at a different level from the sleeping area and/or has multiple levels, and is not separated from the room with a wall greater than 42 inches high above the finish floor level of the sleeping area, the required emergency escape and rescue window or door may be located in the room provided:

1.  The required emergency escape and rescue window or door is directly visually ascertainable from the sleeping area which it serves.

2.  A direct path of travel, which may include stairways, etc., is provided between each sleeping area and its required window or door. More than one sleeping area may use the same egress window or door as long as the emergency escape and rescue window or door serving each sleeping area meets the above requirements.

Section 3B.12.6.3 Alternative Emergency Escape and Rescue in Existing Buildings.

Section 3B.12.6.3.1.

 In an existing building where no exterior wall of the sleeping area of an individual space or JLWQ abuts a public street, public alley, yard or exit court any one of the following alternatives may be used. Signage to indicate the point of emergency egress and rescue and other facilities to ensure ease of access and egress along the escape and rescue path shall be installed to meet the recommendations of the Fire Marshal and the Building Official:

1.  An escape and rescue door may open directly into a corridor if the corridor is constructed to meet the requirements for an extent of stairway enclosure pursuant to Section 1009.4 including provisions for openings and doors, appropriate for the configuration of the building in which it is located. A "Knox Box" with keys shall be provided in an approved location for the Fire Department's use.

2.  A one-hour fire-resistive compartment with one-hour label exit door and equipped with a ships ladder to the roof. A minimum 36 inches by 48 inches clear landing shall be provided in front of the bottom of the ships ladder. Emergency lighting, a counter-balanced roof hatch, and marked exit path across the roof to an approved fire escape or escape ladder shall be provided.

3.  If a court without access to a public way on the property is available, then an approved fire escape or escape ladders may either lead to the roof similar to alternative 2 above, or to the bottom of the court. An approved fire department access path to the bottom of the court shall be provided to meet the recommendations of the Fire Marshal and Building Official. A "Knox Box" shall be provided if there are any locked doors or gates along the fire department access path.

4.  When the roof is part of an alternative emergency escape and rescue method, the roof structure at the exit path and the queuing area to the escape ladder or stair off of the roof shall consider the live loads added to Table 3B.16-A in Section 3B.16. The queuing area provided shall be 3 square feet per occupant for the occupant load served by the alternative emergency escape and rescue.

Section 3B.12.6.3.2 Notice of Limitation.

 If any alternative emergency escape and rescue method is used a "notice of limitation" shall be recorded with the Alameda County Recorder's Office with a waiver of damages and holding the City harmless for any litigation relating to alternative emergency escape and rescue provided.

Section 3B.12.6.3.3 Exit Path Roof Load.

 The roof exit path and a minimum 10 feet square queuing area at the escape stair or ladder off of the roof shall be structurally designed for the loads pursuant to Section 342B.

Section 3B.12.7 Occupant Load.

Section 3B.12.7.1 General.

 Occupant loads for buildings with F-7 occupancies shall comply with CBC Table 1004.1.1 — Maximum Floor Area Allowances Per Occupant for the appropriate use and as herein provided. See Section 3B.16.2 for special provision related to exits for individual spaces due to presence of hazardous materials.

Section 3B.12.7.2 Occupant Load Factor for Individual JLWQ without Employees or Having Regular Hours for Being Open to the Public.

 Occupant load factor for individual JLWQ without employees or having regular hours open to the public shall be 200 square feet per occupant with area based on the superficial floor area of the individual unit.

Section 3B.12.7.3 Occupant Load Factor for Individual JLWQ with Employees and/or Having Regular Hours Open to the Public.

 Occupant load factor for individual JLWQ with employees and/or regular hours open to the public shall be 200 square feet per occupant for the superficial floor area of the designated residential portion of the individual JLWQ and 100 square feet per occupant for the superficial floor area of the non-residential portion of the individual JLWQ.

Section 3B.12.8 Guards.

Section 3B.12.8.1 General.

 Code provisions pertinent to guardrails apply to F-7 occupancies as for an F-1 Occupancy except as herein provided for the individual JLWQ.

Section 3B.12.8.2 Required.

 Guardrails including sleeping mezzanine guardrails for an individual JLWQ may be a minimum of 42 inches in height. A built-in sleeping bunk need not have a guardrail but shall have a railing that has a height of at least one-third of the clear floor to ceiling height measured vertically at the rail. This railing need not exceed 42 inches.

SECTION 3B.13 — Light and Ventilation.

Section 3B.13.1 General.

Code provisions pertinent to the designated residential area of an individual F-7 or R-7 or R7.1 Occupancy shall comply with CBC Section 1203 and 1205 with alternative minimums as provided herein. The remaining area of the individual F-7 or R-7 or R-7.1 Occupancy shall be provided with light, ventilation, and sanitation appropriate to an F-1 Occupancy. F-8 and R-8 Occupancies shall comply with Sections 1203 and 1205.

Section 3B.13.2 Light.

 If due to legal or physical constrains the requirements for natural light in an existing building are not readily achievable, natural light may be provided by means of exterior glazed openings with an area of not less than one-twentieth of the superficial residential floor area of the individual JLWQ with a minimum of 5 square feet if additional artificial light to meet the requirements of the building official is provided. If the sleeping area of an individual space is separated from its required source of natural light by more than 25 feet measured horizontally, then the sleeping area (only) shall be doubled and added to the designated residential area in calculating the required natural light area for a space.

Section 3B.13.3 Ventilation.

 If due to legal or physical constraints the requirements for natural ventilation in an existing building are not readily achievable, natural ventilation may be provided by means of exterior openings with an area of not less than one-fortieth of the superficial residential floor area of the individual space or JLWQ with a minimum of 2 ½ square feet if additional mechanical ventilation to meet the requirements of the building official is provided. If the sleeping area of an individual space or JLWQ is separated from its required source of natural ventilation by more than 25 feet measured horizontally, then the sleeping area (only) shall be doubled and added to the base superficial residential area in calculating the required natural ventilation area for an individual space or JLWQ.

SECTION 3B.14 — Shaft and Exit Enclosures.

Section 3B14.1.

 Code provisions pertinent to F-1 occupancies for shaft and exit enclosures snail apply to an F-7 occupancy JLWQ except that shaft enclosures that serve or are within an individual JLWQ may be the same as required for within an individual dwelling unit of an R-1 Occupancy.

SECTION 3B.15 — Fire Sprinkler and Standpipe Systems.

Section 3B.15.1 Fire Sprinkler System.

 Fire sprinklers for F-7 or R-7 or R-7.1 JLWQ Occupancies shall be provided when required by CBC Section 903.2 and as for an R-2 apartment house pursuant to CBC Section 903.2.8 with an individual JLWQ counted as a dwelling unit in calculating the total number of dwelling units in the building.

Section 3B.15.2 Standpipe System.

 F-7 JLWQ occupancies shall be furnished with standpipes when required by CBC Section 905 as for an F-1 Occupancy. R-7 and R-7.1 Occupancies shall be furnished with standpipes when required by CBC Section 905 as for an R-1 Occupancy.

Section 3B.15.3 Buildings Under Construction.

 Buildings or portions of buildings being converted to JLWQ shall comply with the provisions of Section 905.10 as for new construction.

Section 3B.15.4 Special Provisions for Sprinkler at a Mezzanine, Sleeping Mezzanine, or Built-in Sleeping Bunk.

 A mezzanine with access other than by a stairway, a sleeping mezzanine, or a built-in sleeping bunk shall have a residential quick response sprinkler head at the top of the access to the mezzanine, sleeping mezzanine, or built-in sleeping bunk. See Figure A-3B-4.

SECTION 3B.16 — Special Hazards.

Section 3B.16.1 Storage of Flammable Liquids or Hazardous Materials.

 Allowable Materials and Quantities. Individual F-7 or R-7 Occupancy JLWQ shall comply with Table 3B.16-A and as provided herein. R-7.1 Occupancies shall comply with the Fire Code as for an R-2 Occupancy.

Table 3B.16-A
Criteria for Defining Limits on Use, Storage and Quantities of Hazardous Materials Permitted in Individual JLWQ Spaces

Description R-7 or R-8 Occupancy F-7 or F-8 Occupancy
a) Flammable Liquids:
 Class I-A Prohibited 10 gal. per CA*
 Class I-B or C 1 gal. per unit 15 gal. per CA*
 Class II 5 gal. per unit 30 gal. per CA*
 Class III 5 gal. per unit 80 gal. per CA*
 combined all class 10 gal. per unit NA
 combined I-A, B, C No 30 gal. per CA*
b) Compressed Gas:
 flammable (2) - 1 quart per unit Table 3-D.1 & 3-E UBC per CA*
 corrosives 1 gal. per unit Table 3-D.1 & 3-E UBC per CA*
 Others Table 3-D.1 & 3-E UBC per CA*
c) Corrosives and Toxics 10 gal. per unit, includes quantities from a) and b) above Table 3-E UBC per CA*
d) Additional quantities of a), b), and c) above permitted in approved storage units Yes Table 3-D.1 & 3-E UBC per CA*
e) Woodworking
 less than 3 appliances with dust collectors Yes Yes
 Others No No
f) Other hazardous materials No Table 3-D.1 & 3-E UBC per CA*
CA* = Control Area: the space bounded by 1 hour fire-resistive separation from the other portions of the building. Each building shall have no more than 4 control areas.

Section 3B.16.2 Special Provision.

 When the quantities of hazardous materials in individual F-7 or R-7 Occupancies do not exceed the following Table 3B.16-A no additional requirements apply. If the quantities of hazardous materials in an individual F-7 Occupancy JLWQ exceed the following Table 3B.16-A but do not exceed those listed in CBC Table No. 307.1 (1) or (2), the requirements of CBC Section 307 apply and occupants in such individual spaces where the work area exceeds 200 square feet (which is the case for all individual spaces or JLWQ) shall have access to at least two exits from the room and all portions of the work area shall be within 75 feet of an exit. When the quantities of hazardous materials in such uses exceed those allowed by CBC Table No. 307.1 (1) or (2), the use shall be classified by the Building Official in the appropriate Group H Occupancy.

 An F-7 Occupancy shall not be used for storage of flammable liquids or hazardous materials where welding, any work involving an open flame, or similar hazardous operations or processes are accomplished except as herein provided.

EXCEPTIONS:

1.  Open flame may be used for art work, craft work, or similar activities provided the quantity of compressed gas or flammable liquid stored within an individual F-7 Occupancy JLWQ complies with Table 353B-A.

2.  Open flame and welding may be permitted in an individual F-7 Occupancy JLWQ if the individual F-7 Occupancy JLWQ with the open flame and welding has an occupancy separation from the remainder of the building or other JLWQ in the building pursuant to Section 307 for the appropriate Group H occupancy.

SECTION 3B.17 — Fire Alarms.

Section 3B.17.1 General.

 F-7 JLWQ occupancies shall conform to the requirements as for an R-2 apartment house pursuant to CBC Section 907.2.9 and as provided herein. An individual JLWQ is considered a dwelling unit for purposes of this section.

Section 3B.17.2 Special Provision for Local Alarm.

 If a common interior exit path serves more than 4 individual F-7 and/or R-7 or R-7.1 Occupancy JLWQ or serves F-7 and/or R-7 or R-7.1 Occupancy JLWQ spaces that combined accommodate more than 10 persons, and the exit path or the spaces it serves are not fire-sprinklered, then an approved local manual or automatic fire alarm system shall be installed in the exit path. The local alarm shall be capable of sounding an audible alarm to the individual JLWQs served by the common interior exit path to meet the recommendations of the Fire Marshal and Building Official.

SECTION 3B.18 — Sound Transmission Control.

Section 3B.18.1 General.

 Individual JLWQ shall comply with CBC Section 1207 as for apartment houses and as provided in this division. Existing buildings being converted to JLWQ Occupancies are not required to, but are recommended to, consider exterior noise sources pursuant to Section 1207.11.

EXCEPTION: In existing buildings existing walls and floor/ceilings are not required to meet these requirements unless they are opened or altered.

Section 3B.18.2 Notice of Limitation.

 A "notice of limitation" pursuant to Section 3B.3.5 shall be provided for all F-7 or 8 Occupancies where individual JLWQ are abutting other habitable spaces.

Section 3B.18.3 Airborne Sound Insulation.

Section 3B.18.3.1 General.

 Buildings or a portion of buildings classified as F-7 or 8 or R-7 or R-7.1 or 8 Occupancies shall comply with CBC Section 1207.7 as for apartment houses by providing STC 50 walls and floor/ceilings where a designated residential area abuts another occupied area and as provided in this division.

Section 3B.18.3.2 Commercially/Industrially Oriented JLWQ as Noise Source.

 Any individual F-7 or 8 Occupancy space that is a source of noise above 60db such as a rock band practice shall add construction elements that provide an additional 50 STC to the existing walls and floor/ceiling that abuts adjacent residential occupancies. Alternatively, the space may comply with the recommendations of an acoustic analysis report, prepared under the supervision of a person experienced in the field of acoustical engineering, submitted with an application for building permit.

Section 3B.18.4 Impact Insulation.

Section 3B.18.4.1 General.

 Buildings or a portion of buildings with individual spaces or JLWQ shall comply with CBC Section 1207.8 as for apartment houses by providing C 50 floor/ceilings where a designated residential area abuts another occupied area and as provided in this division.

Section 3B.18.4.2 Commercially/Industrially Oriented JLWQ as Noise Source.

 Any individual F-7 JLWQ space that is a source of impact noise above 60db shall add construction elements to separate the source of impact noise or provide an additional STC 50 to the floor/ceiling that abuts adjacent residential occupancies. Alternatively, the space may comply with the recommendations of an acoustic analysis.

SECTION 3B.19 — Energy Conservation Requirements.

Section 3B.19.1 General.

 The space of buildings or portions of buildings with commercially/industrially-oriented JLWQ outside the area of the individual JLWQ shall comply with the appropriate California Energy Commission's Residential or the residential portion of the Non-residential Standards. Individual JLWQ units themselves shall comply as follows:

1.  Either the Residential Standards may be applied or alternatively the residential portion of the Non-residential Standards may be applied (as appropriately indicated on information on plans) to individual JLWQ in buildings as follows:

1.1  Buildings of any number of stories with a maximum of two JLWQ and/or dwelling units.

1.2  Buildings with any number of individual JLWQ and/or dwelling units and with three or fewer habitable stories.

2.  The residential portion of the Non-residential Standards shall apply to individual JLWQ in buildings as follows:

2.1  Buildings of any number of stories with more than two JLWQ and/or dwelling units.

2.2  Buildings with more than three habitable stories.

SECTION 3B.20 — Plumbing Systems Requirements.

Section 3B.20.1 General.

 F-7 or 8 and R-7, R-7.1 or 8 Occupancies shall comply with requirements of the current California Plumbing Code as herein provided.

Section 3B.20.2 Plumbing Code Application.

 Plumbing Code requirements as for an F occupancy apply to Group F-7 or F-8 Occupancies except that Section 701.1.2 of the California Plumbing Code which allows ABS and PVC installations in residential construction not more than two stories in height may be applied to plumbing within individual commercial/indus-trially oriented JLWQ that individually have no more than two stories. Plumbing in party and common walls and floor/ceilings are not considered within the individual JLWQ.

Section 3B.20.3 Number of Fixtures.

 Individual JLWQ shall meet the requirements of Table 4-1 of the California Plumbing Code for Group R Occupancies. The common use areas of the building and areas with employees or open to the public shall comply with the requirements of Table 4-1 of the California Plumbing Code for F Occupancies.

SECTION 3B.21 — Electrical Code Requirements.

Section 3B.21.1 General.

 A Group F-7 or 8 Occupancy shall conform with the California Electrical Code requirements as for an F-1 Occupancy. The designated residential area of an individual F-7 or 8 Occupancy JLWQ shall comply with Section 210-52 relating to dwelling unit receptacle outlets. Group R7, R-7.1 or 8 Occupancy shall conform with requirements as for an R-2 Occupancy.

15-04-697a.jpg

15-04-697b.jpg

15-04-697c.jpg

15-04-697d.jpg

15-04-697e.jpg

15-04-697f.jpg

15-04-697g.jpg

15-04-697h.jpg

15-04-697i.jpg

15-04-697j.jpg

(Ord. No. 13047, §§ 2, 3, 11-9-2010)